Effects of assessment and processing techniques on the shape of arterial pressure-distension loops

被引:32
作者
Hoeks, APG
Willigers, JM
Reneman, RS
机构
[1] Maastricht Univ, Dept Biophys, Cardiovasc Res Inst Maastricht, NL-6200 MD Maastricht, Netherlands
[2] Maastricht Univ, Cardiovasc Res Inst Maastricht, Dept Physiol, Maastricht, Netherlands
关键词
arteries; dynamics; blood pressure; elasticity; hysteresis;
D O I
10.1159/000054082
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The dynamic mechanical characteristics of the arterial wall, especially its alinearity and viscoelastic behaviour, are revealed by pressure-distension loops, where the change in diameter (distension) of a lumen is plotted as a function of the change in transmural pressure. For linearity, the pressure-distension loop should be closed and straight, while viscous behavior results in an open loop, For a correct interpretation of the loops, it is essential that both distension and pressure are recorded simultaneously at the same location and processed by circuitries having the same frequency characteristics. The present paper aims at quantifying the effect of misalignment in recording position and of mismatch in frequency characteristics by analyzing the distension and pressure waveforms obtained at known locations in a phantom rig under pulsatile conditions with equipment with a validated frequency response. It is concluded that misalignment of only a few millimeters or mismatch in frequency response, even if the cutoff frequencies are far beyond the signal frequencies of interest, strongly affects the shape of the pressure-distension loop. If the forward and reflected pressure wave partially coincide, position misalignment cannot adequately be corrected for. The frequency mismatch, however, can be corrected for by crosswise preprocessing a waveform by a filter with the frequency response of the registration equipment used for the recording of the other waveform, It is important to consider these artifacts in interpreting pressure-distension loops in the clinical situation, Copyright (C) 2000 S. Karger AG, Basel.
引用
收藏
页码:494 / 500
页数:7
相关论文
共 20 条
[1]   EFFECTS OF HYPERTENSION ON VISCOELASTICITY OF CAROTID AND FEMORAL ARTERIES IN HUMANS [J].
ARMENTANO, R ;
MEGNIEN, JL ;
SIMON, A ;
BELLENFANT, F ;
BARRA, J ;
LEVENSON, J .
HYPERTENSION, 1995, 26 (01) :48-54
[2]   SEPARATE DETERMINATION OF THE PULSATILE ELASTIC AND VISCOUS FORCES DEVELOPED IN THE ARTERIAL-WALL INVIVO [J].
BAUER, RD ;
BUSSE, R ;
SCHABERT, A ;
SUMMA, Y ;
WETTERER, E .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1979, 380 (03) :221-226
[3]   In vivo in vitro comparison of rat abdominal aorta wall viscosity - Influence of endothelial function [J].
Boutouyrie, P ;
Bezie, Y ;
Lacolley, P ;
Challande, P ;
ChamiotClerc, P ;
Benetos, A ;
delaFaverie, JFR ;
Safar, M ;
Laurent, S .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (07) :1346-1355
[4]   Smooth muscle tone and arterial wall viscosity - An in vivo in vitro study [J].
Boutouyrie, P ;
Boumaza, S ;
Challande, P ;
Lacolley, P ;
Laurent, S .
HYPERTENSION, 1998, 32 (02) :360-364
[5]  
Brands P J, 1999, Eur J Ultrasound, V9, P257, DOI 10.1016/S0929-8266(99)00033-6
[6]   A radio frequency domain complex cross-correlation model to estimate blood flow velocity and tissue motion by means of ultrasound [J].
Brands, PJ ;
Hoeks, APG ;
Ledoux, LAF ;
Reneman, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :911-920
[7]   MECHANICAL-PROPERTIES OF EXPOSED HUMAN COMMON CAROTID ARTERIES INVIVO [J].
BUSSE, R ;
BAUER, RD ;
SCHABERT, A ;
SUMMA, Y ;
BUMM, P ;
WETTERER, E .
BASIC RESEARCH IN CARDIOLOGY, 1979, 74 (05) :545-554
[8]   FLOW-DIAMETER PHASE-SHIFT - A POTENTIAL INDICATOR OF CONDUIT ARTERY FUNCTION [J].
HAYOZ, D ;
BERNARDI, L ;
NOLL, G ;
WEBER, R ;
PORRET, CA ;
PASSINO, C ;
WENZEL, R ;
STERGIOPULOS, N .
HYPERTENSION, 1995, 26 (01) :20-25
[9]  
HOCKS APG, 1990, ULTRASOUND MED BIOL, V16, P121
[10]   BIOPHYSICAL PRINCIPLES OF VASCULAR DIAGNOSIS [J].
HOEKS, APG ;
RENEMAN, RS .
JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (02) :71-79