Accuracy of ground-based microwave radiometer and balloon-borne measurements during the WVIOP2000 field experiment

被引:30
作者
Cimini, D [1 ]
Westwater, ER
Han, Y
Keihm, SJ
机构
[1] Univ Aquila, CETEMPS, I-67010 Coppito, Italy
[2] Univ Colorado, NOAA, Cooperat Inst Res Environm Sci, Environm Technol Lab, Boulder, CO 80305 USA
[3] NOAA, Natl Environm Satellite Data & Informat Serv, Off Res & Appl, Camp Springs, MD 20746 USA
[4] CALTECH, Jet Prop Lab, Pasadena, CA 91109 USA
来源
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING | 2003年 / 41卷 / 11期
关键词
microwave radiometry; radiometric accuracy; radiometric calibration; water vapor;
D O I
10.1109/TGRS.2003.815673
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
We discuss the performances of a set of four microwave water vapor radiometers operating in the 20-30-GHz band during a field experiment, with an emphasis on calibration and achievable accuracy. The field experiment was conducted at the Department of Energy's Atmospheric Radiation Measurement Program's field site in north central Oklahoma, and was focused on clear-sky water vapor measurements by both radiometers and radiosondes. A comparison between two published radiometric tip curve calibration procedures is presented, and these procedures are applied to measurements from two nearly identical instruments placed a few meters apart. Using the instantaneous tip cal method of the Environmental Technology Laboratory, the brightness temperature measurements for the two identical instruments differed by less than 0.2 K over a 24-h period. Results from reference load cryogenic tests and brightness temperature cross comparisons have shown differences within 0.7 K. In addition, we compare radiometric measurements with calculations of brightness temperature based on the Rosenkranz absorption model and radiosonde observations. During the experiment, both Vaisala-type RS80 and RS90 humidity sensors were used. Our comparisons demonstrate the improvements achieved by the new Vaisala RS90 sensors in atmospheric humidity profiling, which reduce or eliminate the "dry bias" problem.
引用
收藏
页码:2605 / 2615
页数:11
相关论文
共 37 条
[1]   The Atmospheric Radiation Measurement program [J].
Ackerman, TP ;
Stokes, GM .
PHYSICS TODAY, 2003, 56 (01) :38-44
[2]  
CIMINI D, 2002, P COST720 M AQ IT JU
[3]  
CIMINI D, 2003, P IGARSS TOUL FRANC
[4]  
Clough S., 1996, P 6 ARM SCI TEAM M S
[5]  
CLOUGH SA, 1995, 1995 OSA TECHNICAL D, V2, P76
[6]  
Guichard F, 2000, J CLIMATE, V13, P3611, DOI 10.1175/1520-0442(2000)013<3611:TARIOT>2.0.CO
[7]  
2
[8]   Infrared spectral radiance measurements in the tropical Pacific atmosphere [J].
Han, Y ;
Shaw, JA ;
Churnside, JH ;
Brown, PD ;
Clough, SA .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1997, 102 (D4) :4353-4356
[9]   Analysis and improvement of tipping calibration for ground-based microwave radiometers [J].
Han, Y ;
Westwater, ER .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2000, 38 (03) :1260-1276
[10]  
HAN Y, 2000, P 10 ARM SCI TEAM M