Microstrip RF surface coil design for extremely high-field MRI and spectroscopy

被引:168
作者
Zhang, XL [1 ]
Ugurbil, K [1 ]
Chen, W [1 ]
机构
[1] Univ Minnesota, Sch Med, Dept Radiol, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
7; Tesla; microstrip resonator; RF coil; surface coil; high field; MR imaging; brain;
D O I
10.1002/mrm.1212
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
A new type of high-frequency RF surface coil was developed for in vivo proton or other nuclei NMR applications at 7T. This is a purely distributed-element and transmission line design. The coil consists of a thin strip conductor (copper or silver) and a ground plane separated by a low-loss dielectric material with a thickness (H). Due to its specific semi-open transmission line structure, substantial electromagnetic energy is stored in the dielectric material between the thin conductor and the ground plane, which results in a reduced radiation loss and a reduced perturbation of sample loading to the RF coil compared to conventional surface coils. The coil is characterized by a high Q factor, no RF shielding, small physical coil size, lower cost, and easy fabrication. A brief theoretical description of the microstrip RF coil is given that can be used to guide the coil designs. A set of gradient-recalled echo images were acquired by using the single- and two-turn microstrip RF surface coils from both phantom and human brain at 7T, which show good penetration and sensitivity. The two-turn coil design significantly improves the Bi symmetry as predicted by the microstrip theory. The optimum H for microstrip surface coils is approximately 7 mm. This coil geometry yields a B-1 penetration similar to that of conventional surface coils. SNR comparison was made between the microstrip coil and conventional surface coils with and without RF shielding. The results reveal that the novel surface coil design based on the microstrip concept makes very high-field MRI/MRS more convenient and efficient in research and future clinics. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 18 条
[1]
Adriany G., 2000, P 8 ANN M ISMRM DENV, P563
[2]
ADRIANY G, 1998, THESIS U AACHEN AACH
[3]
BAHL IJ, 1977, MICROWAVES, V16, P174
[4]
Chen CN, 1989, BIOMEDICAL MAGNETIC
[5]
Crozier S, 1997, CONCEPT MAGNETIC RES, V9, P195, DOI 10.1002/(SICI)1099-0534(1997)9:4<195::AID-CMR1>3.0.CO
[6]
2-U
[7]
Hoult DI, 2000, J MAGN RESON IMAGING, V12, P46, DOI 10.1002/1522-2586(200007)12:1<46::AID-JMRI6>3.0.CO
[8]
2-D
[9]
SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT [J].
HOULT, DI ;
RICHARDS, RE .
JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) :71-85
[10]
ELECTROMAGNETIC-FIELDS OF SURFACE COIL INVIVO NMR AT HIGH-FREQUENCIES [J].
KELTNER, JR ;
CARLSON, JW ;
ROOS, MS ;
WONG, STS ;
WONG, TL ;
BUDINGER, TF .