Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) generally shows better mass sensitivity for arginine-terminated peptides than for lysine-terminated peptides, presumed to arise from the higher proton affinity of the guanidine group in arginine. Here, we report a new method for analyzing phosphopeptides in which phosphopeptides are labeled with a novel chemical tag, guanidinoethanethiol (GET), by a beta-elimination/Michael addition before MS analysis. GET labeling converts phosphoserine into guanidinoethylcysteine (Gec) containing a guanidine moiety, along with an increase in mass of 21.1 Da. GET-labeled peptides are detected by MALDI MS with greatly increased peak intensities compared to those of intact phosphopeptides. In particular, GET labeling of lysine-terminated phosphopeptides dramatically increased peak intensity. GET labeling of lysine-terminated phosphopeptides improved sensitivity up to 22 times compared to that of the corresponding aminoethanethiol (AET) labeling, in which AET was used as a labeling tag containing an amino group instead of the guanidine group. These results show the guanidine group plays a very important role in increasing the observed sensitivity of MALDI MS for labeled peptide, derivatized from serine-phosphorylated peptides. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:2204 / 2210
页数:7
相关论文
共 21 条
[1]   Dynamic identification of phosphopeptides using immobilized metal ion affinity chromatography enrichment, subsequent partial β-elimination/chemical tagging and matrix-assisted laser desorption/ionization mass spectrometric analysis [J].
Ahn, YH ;
Park, EJ ;
Cho, K ;
Kim, JY ;
Hal, SH ;
Ryu, SH ;
Yoo, JS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (20) :2495-2501
[2]   Chemical derivatization of phosphoserine and phosphothreonine containing peptides to increase sensitivity for MALDI-based analysis and for selectivity of MS/MS analysis [J].
Arrigoni, G ;
Resjö, S ;
Levander, F ;
Nilsson, R ;
Degerman, E ;
Quadroni, M ;
Pinna, LA ;
James, P .
PROTEOMICS, 2006, 6 (03) :757-766
[3]  
Beardsley RL, 2000, RAPID COMMUN MASS SP, V14, P2147, DOI 10.1002/1097-0231(20001215)14:23<2147::AID-RCM145>3.0.CO
[4]  
2-M
[5]  
Brancia FL, 2000, RAPID COMMUN MASS SP, V14, P2070, DOI 10.1002/1097-0231(20001115)14:21<2070::AID-RCM133>3.0.CO
[6]  
2-G
[7]   RAPID AND SELECTIVE MODIFICATION OF PHOSPHOSERINE RESIDUES CATALYZED BY BA2+ IONS FOR THEIR DETECTION DURING PEPTIDE MICROSEQUENCING [J].
BYFORD, MF .
BIOCHEMICAL JOURNAL, 1991, 280 :261-265
[8]   Protein phosphorylation and signal transduction [J].
Graves, JD ;
Krebs, EG .
PHARMACOLOGY & THERAPEUTICS, 1999, 82 (2-3) :111-121
[9]   Increased sensitivity of tryptic peptide detection by MALDI-TOF mass spectrometry is achieved by conversion of lysine to homoarginine [J].
Hale, JE ;
Butler, JP ;
Knierman, MD ;
Becker, GW .
ANALYTICAL BIOCHEMISTRY, 2000, 287 (01) :110-117
[10]   Signaling - 2000 and beyond [J].
Hunter, T .
CELL, 2000, 100 (01) :113-127