Assessment of normal tricuspid valve anatomy in adults by real-time three-dimensional echocardiography

被引:107
作者
Anwar, Ashraf M.
Geleijnse, Marcel L.
Soliman, Osama I. I.
McGhie, Jackie S.
Frowijn, Rene
Nemes, Attila
van den Bosch, Annemien E.
Galema, Tjebbe W.
ten Cate, Folkert J.
机构
[1] Erasmus MC, Thoraxctr, NL-3015 GD Rotterdam, Netherlands
[2] Al Azhar Univ, Al Husein Univ Hosp, Dept Cardiol, Cairo, Egypt
关键词
normal tricuspid valve; tricuspid valve anatomical structure; real-time three-dimensional echocardiography;
D O I
10.1007/s10554-007-9210-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The tricuspid valve (TV) is a complex structure. Unlike the aortic and mitral valve it is not possible to visualize all TV leaflets simultaneously in one cross-sectional view by standard two-dimensional echocardiography (2DE) either transthoracic or transesophageal due to the position of TV in the far field. Aim Quantitative and qualitative assessment of the normal TV using real-time 3-dimensional echocardiography (RT3DE). Methods RT3DE was performed for 100 normal adults (mean age 30 +/- 9 years, 65% males). RT3DE visualization was evaluated by 4-point score (1: not visualized, 2: inadequate, 3: sufficient, and 4: excellent). Measurements included TV annulus diameters (TAD), TV area (TVA), and commissural width. Results In 90% of patients with good 2DE image quality, it was possible to analyse TV anatomy by RT3DE. A detailed anatomical structure including unique description and measurement of tricuspid annulus shape and size, TV leaflets shape, and mobility, and TV commissural width were obtained in majority of patients. Identification of each TV leaflet as seen in the routine 2DE views was obtained. Conclusion RT3DE of the TV is feasible in a large number of patients. RT3DE may add to functional 2DE data in description of TV anatomy and providing highly reproducible and actual reality (anatomical and functional) measurements.
引用
收藏
页码:717 / 724
页数:8
相关论文
共 22 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Tricuspid regurgitation secondary to mitral valve disease: Tricuspid annulus function as guide to tricuspid valve repair [J].
Colombo, T ;
Russo, C ;
Ciliberto, GR ;
Lanfranconi, M ;
Bruschi, G ;
Agati, S ;
Vitali, E .
CARDIOVASCULAR SURGERY, 2001, 9 (04) :369-377
[3]   ADJUSTABLE TRICUSPID-VALVE ANNULOPLASTY ASSISTED BY INTRAOPERATIVE TRANSESOPHAGEAL COLOR DOPPLER ECHOCARDIOGRAPHY [J].
DESIMONE, R ;
LANGE, R ;
TANZEEM, A ;
GAMS, E ;
HAGL, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (11) :926-931
[4]  
Faletra F, 2005, Heart, V91, P499, DOI 10.1136/hrt.2004.041459
[5]  
Feigenbaum H., 2005, Feigenbaum's Echocardiography, V6th ed.
[6]  
GOLDMAN ME, 1987, J THORAC CARDIOV SUR, V94, P542
[7]   FORMATION OF THE TRICUSPID-VALVE IN THE HUMAN HEART [J].
LAMERS, WH ;
VIRAGH, S ;
WESSELS, A ;
MOORMAN, AFM ;
ANDERSON, RH .
CIRCULATION, 1995, 91 (01) :111-121
[8]   Real-time three-dimensional intracardiac echocardiography [J].
Light, ED ;
Idriss, SF ;
Wolf, PD ;
Smith, SW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (09) :1177-1183
[9]   Assessment of the tricuspid valve: A comparison of four transesophageal echocardiographic windows [J].
Maslow, AD ;
Schwartz, C ;
Singh, AK .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2004, 18 (06) :719-724
[10]  
Nekkanti Rajasekhar, 2002, Am J Geriatr Cardiol, V11, P329, DOI 10.1111/j.1076-7460.2002.00886.x