Evaluation of an on-line coupled continuous flow liquid membrane extraction and precolumn system as trace enrichment technique by liquid chromatographic determination of bisphenol A

被引:17
作者
Liu, JF
Liang, X
Jiang, GB
Cai, YQ
Zhou, QX
Liu, GG
机构
[1] Chinese Acad Sci, Ecoenvironm Sci Res Ctr, Key Lab Environm Chem & Ecotoxicol, Beijing 100085, Peoples R China
[2] Henan Normal Univ, Coll Environm Sci & Chem, Key Lab Environm Sci & Engn, Xinxiang 453002, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
on-line enrichment; continuous flow liquid membrane extraction; precolumn; bisphenol A; water samples;
D O I
10.1016/S0039-9140(03)00216-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line coupled continuous flow liquid membrane extraction (CFLME) and C-18 precolumn system was developed for sample preconcentration in liquid chromatography determination. After preconcentration by CFLME, which is based on the combination of continuous flow liquid-liquid extraction and supported liquid membrane, bisphenol A (BPA) was enriched in 960 mul of 1 mol l(-1) NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C-18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto a C-18 analytical column for separation and detected at 220 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor, and enrichment time were optimized. The proposed method presents a detection limit of 0.03 mug l(-1) (S/N = 3) when 60 ml samples was enriched with an enrichment time of 30 min. Compared with C-18 based column-switching procedure, this proposed procedure presents similar sample throughput and lower detection limits. The proposed method was successfully applied to determine BPA in tap water, river water, and municipal sewage effluent samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1155 / 1161
页数:7
相关论文
共 15 条
[1]   Determination of sulfonylurea herbicides by continuous-flow liquid membrane extraction on-line coupled with high-performance liquid chromatography [J].
Chao, JB ;
Liu, JF ;
Wen, MJ ;
Liu, JM ;
Cai, YQ ;
Jiang, GB .
JOURNAL OF CHROMATOGRAPHY A, 2002, 955 (02) :183-189
[2]   Determination of bisphenol A (BPA) in water by gas chromatography mass spectrometry [J].
delOlmo, M ;
GonzalezCasado, A ;
Navas, NA ;
Vilchez, JL .
ANALYTICA CHIMICA ACTA, 1997, 346 (01) :87-92
[3]   Characterization and distribution of trace organic contaminants in sediment from Masan Bay, Korea. 1. Instrumental analysis [J].
Khim, JS ;
Kannan, K ;
Villeneuve, DL ;
Koh, CH ;
Giesy, JP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (23) :4199-4205
[4]   Supported liquid membrane work-up in combination with liquid chromatography and electrochemical detection for the determination of chlorinated phenols in natural water samples [J].
Knutsson, M ;
Mathiasson, L ;
Jonsson, JA .
CHROMATOGRAPHIA, 1996, 42 (3-4) :165-170
[5]   Determination of endocrine-disrupting phenolic compounds and estrogens in surface and drinking water by HRGC-(NCI)-MS in the picogram per liter range [J].
Kuch, HM ;
Ballschmiter, K .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (15) :3201-3206
[6]  
Lee HB, 2000, J AOAC INT, V83, P290
[7]   Continuous flow liquid membrane extraction: a novel automatic trace-enrichment technique based on continuous flow liquid-liquid extraction combined with supported liquid membrane [J].
Liu, JF ;
Chao, JB ;
Jiang, GB .
ANALYTICA CHIMICA ACTA, 2002, 455 (01) :93-101
[8]  
Liu JF, 2001, J SEP SCI, V24, P874, DOI 10.1002/1615-9314(20011101)24:10/11<874::AID-JSSC874>3.0.CO
[9]  
2-U
[10]  
Motoyama A, 1999, RAPID COMMUN MASS SP, V13, P2204, DOI 10.1002/(SICI)1097-0231(19991115)13:21<2204::AID-RCM776>3.3.CO