Performance study of an innovative natural gas CHP system

被引:27
作者
Fu, Lin [1 ]
Zhao, Xiling [1 ]
Zhang, Shigang [1 ]
Li, Yan [1 ]
Jiang, Yi [1 ]
Li, Hui [1 ]
Sun, Zuoliang [1 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Sch Architecture, Beijing 100084, Peoples R China
关键词
BCHP; Steady performance; Dynamic performance; LABORATORY RESEARCH; ENGINE; DRIVEN;
D O I
10.1016/j.enconman.2010.07.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the last decade, technological innovation and changes in the economic and regulatory environment have resulted in increased attention to distributed energy systems (DES). Combined cooling heating and power (CHP) systems based on the gas-powered internal combustion engine (ICE) are increasingly used as small-scale distribution co-generators. This paper describes an innovative ICE-CHP system with an exhaust-gas-driven absorption heat pump (AHP) that has been set up at the energy-saving building in Beijing, China. The system is composed of an ICE, an exhaust-gas-driven AHP, and a flue gas condensation heat exchanger (CHE), which could recover both the sensible and latent heat of the flue gas. The steady performance and dynamic response of the innovative CHP system with different operation modes were tested. The results show that the system's energy utilization efficiency could reach above 90% based on lower heating value (LHV) of natural gas; that is, the innovative CHP system could increase the heat utilization efficiency 10% compared to conventional CHP systems, and the thermally activated components of the system have much more thermal inertia than the electricity generation component. The detailed test results provide important insight into CHP performance characteristics and could be valuable references for the control of CHP systems. The novel CHP system could take on a very important role in the CHP market. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:321 / 328
页数:8
相关论文
共 16 条
[1]  
Beckwith T.G., 1993, MECH MEASUREMENTS, V5 th
[2]   Laboratory research on combined cooling, heating and power (CCHP) systems [J].
Fu, L. ;
Zhao, X. L. ;
Zhang, S. G. ;
Jiang, Y. ;
Li, H. ;
Yang, W. W. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (04) :977-982
[3]  
FU L, 2000, INT J ENERGY, V25, P283
[4]   Performance evaluation of a tri-generation system with simulation and experiment [J].
Ge, Y. T. ;
Tassou, S. A. ;
Chaer, I. ;
Suguartha, N. .
APPLIED ENERGY, 2009, 86 (11) :2317-2326
[5]   Optimal operation of a micro-combined cooling, heating and power system driven by a gas engine [J].
Kong, X. Q. ;
Wang, R. Z. ;
Li, Y. ;
Huang, X. H. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (03) :530-538
[6]   Energy efficiency and economic feasibility of CCHP driven by stirling engine [J].
Kong, XQ ;
Wang, RZ ;
Huang, XH .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (9-10) :1433-1442
[7]  
Liao X., 2004, THESIS U MARYLAND CO
[8]   Annual performance of liquid desiccant based independent humidity control HVAC system [J].
Liu, Xiaohua ;
Li, Zhen ;
Jiang, Yi ;
Lin, Borong .
APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) :1198-1207
[9]   Combined cooling and heating using a gas engine in a supermarket [J].
Maidment, GG ;
Zhao, X ;
Riffat, SB .
APPLIED ENERGY, 2001, 68 (04) :321-335
[10]  