CO2 and gadopentetate dimeglumine as alternative contrast agents for malfunctioning dialysis grafts and fistulas

被引:19
作者
Spinosa, DJ
Angle, JF
Hagspiel, KD
Schenk, WG
Matsumoto, AH
机构
[1] Univ Virginia, Hlth Sci Ctr, Dept Radiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Hlth Sci Ctr, Dept Surg, Charlottesville, VA 22908 USA
关键词
hemodialysis; fistulas; grafts; dimeglumine; angiography; carbon dioxide;
D O I
10.1046/j.1523-1755.1998.00047.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background. Hemodialysis grafts and native fistulas are frequently evaluated angiographically utilizing iodinated contrast material to determine the cause of malfunction. Occasionally, patients are not able to receive iodinated contrast material due to a history of previous severe allergic reaction or concern that iodinated contrast material could worsen renal function requiring premature initiation of permanent dialysis. We set out to test the feasibility of gadopentetate dimeglumine as an alternative contrast agent in conjunction with carbon dioxide (CO2) angiography in the evaluation and treatment of hemodialysis grafts and native fistulas in patients who have a contraindication to iodinated contrast material. Methods. Six patients with a malfunctioning hemodialysis graft and native fistula were evaluated. Four patients were successfully evaluated using carbon dioxide and gadopentetate dimeglumine. Two additional patients underwent balloon angioplasty using gadopentetate dimeglumine alone as the alternative contrast agent. Results. All six patients successfully were evaluated and treated using gadopentetate dimeglumine either alone or as a supplement to CO2 angiography. Five of these patients had lesions successfully treated using gadopentetate dimeglumine alone or in combination with CO2 as the angiographic contrast agents. One patient underwent a successful diagnostic angiogram using gadopentetate dimeglumine and CO2 as alternative contrast agents and was subsequently treated with surgical revision. The gadopentetate dimeglumine angiograms identified the arterial anastomosis and more clearly identified stenotic lesions and venous outflow anatomy compared to carbon dioxide angiograms. Conclusion. Gadopentetate dimeglumine is useful as an alternative contrast agent in conjunction with CO2 in patients with malfunctioning hemodialysis grafts and fistulas, who have a contraindication to the administration of iodinated contrast material.
引用
收藏
页码:945 / 950
页数:6
相关论文
共 16 条
[1]
COMPARISON OF DIAGNOSTIC-ACCURACY WITH CARBON-DIOXIDE VERSUS IODINATED CONTRAST MATERIAL IN THE IMAGING OF HEMODIALYSIS ACCESS FISTULAS [J].
EHRMAN, KO ;
TABER, TE ;
GAYLORD, GM ;
BROWN, PB ;
HAGE, JP .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) :771-775
[2]
Fobbe F, 1996, EUR RADIOL, V6, P224
[3]
TREATMENT OF STENOTIC LESIONS IN DIALYSIS ACCESS FISTULAS AND SHUNTS BY TRANS-LUMINAL ANGIOPLASTY [J].
GORDON, DH ;
GLANZ, S ;
BUTT, KM ;
ADAMSONS, RJ ;
KOENIG, MA .
RADIOLOGY, 1982, 143 (01) :53-58
[4]
HARTMAN G, 1982, AJR, V139, P914
[5]
RENAL TOLERANCE OF GADOLINIUM-DTPA DIMEGLUMINE IN PATIENTS WITH CHRONIC-RENAL-FAILURE [J].
HAUSTEIN, J ;
NIENDORF, HP ;
KRESTIN, G ;
LOUTON, T ;
SCHUHMANNGIAMPIERI, G ;
CLAUSS, W ;
JUNGE, W .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :153-156
[6]
PLASTIC BAG DELIVERY SYSTEM FOR HAND INJECTION OF CARBON-DIOXIDE [J].
HAWKINS, IF ;
CARIDI, JG ;
KERNS, SR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1487-1489
[7]
ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA [J].
KATAYAMA, H ;
YAMAGUCHI, K ;
KOZUKA, T ;
TAKASHIMA, T ;
SEEZ, P ;
MATSUURA, K .
RADIOLOGY, 1990, 175 (03) :621-628
[8]
Renal insufficiency: Gadopentetate dimeglumine as a radiographic contrast agent during peripheral vascular interventional procedures [J].
Kaufman, JA ;
Geller, SC ;
Waltman, AC .
RADIOLOGY, 1996, 198 (02) :579-581
[9]
Adverse reactions to gadolinium contrast media: A review of 36 cases [J].
Murphy, KJ ;
Brunberg, JA ;
Cohan, RH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) :847-849
[10]
Niendorf Hans Peter, 1993, P11