Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents

被引:41
作者
Maï, W [1 ]
Badea, CT [1 ]
Wheeler, CT [1 ]
Hedlund, LW [1 ]
Johnson, GA [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USA
关键词
resolution; motion; rodent; magnetic resonance imaging; digital microradiography;
D O I
10.1002/mrm.20400
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One can acquire high-resolution pulmonary and cardiac images in live rodents with MR microscopy by synchronizing the image acquisition to the breathing cycle across multiple breaths, and gating to the cardiac cycle. The precision with which one can synchronize image acquisition to the motion defines the ultimate resolution limit that can be attained in such studies. The present work was performed to evaluate how reliably the pulmonary and cardiac structures return to the same position from breath to breath and beat to beat across the prolonged period required for MR microscopy. Radiopaque beads were surgically glued to the abdominal surface of the diaphragm and on the cardiac ventricles of anesthetized, mechanically ventilated rats. We evaluated the range of motion for the beads (relative to a reference vertebral bead) using digital microradiography with two specific biological gating methods: 1) ventilation synchronous acquisition, and 2) both ventilation synchronous and cardiac-gated acquisitions. The standard deviation (SD) of the displacement was <= 100 mu m, which is comparable to the resolution limit for in vivo MRI imposed by signal-to-noise ratio (SNR) constraints. With careful control of motion, its impact on resolution can be limited. This work provides the first quantitative measure of the motion-imposed resolution limits for in vivo imaging. Magn Reson Med 53:858-865, 2005. (c) 2005 WileyLiss, Inc.
引用
收藏
页码:858 / 865
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 2002, CARDIOPULMONARY ANAT
[2]   MRI of lung parenchyma in rats and mice using a gradient-echo sequence [J].
Beckmann, N ;
Tigani, B ;
Mazzoni, L ;
Fozard, JR .
NMR IN BIOMEDICINE, 2001, 14 (05) :297-306
[3]   EFFECT OF RESPIRATION ON CARDIAC MOTION DETERMINED BY CINEANGIOGRAPHY - IMPLICATIONS CONCERNING 3-DIMENSIONAL HEART RECONSTRUCTION USING COMPUTER TOMOGRAPHY [J].
BOGREN, HG ;
LANTZ, BMT ;
MILLER, RR ;
MASON, DT .
ACTA RADIOLOGICA-DIAGNOSIS, 1977, 18 (06) :609-620
[4]   Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction [J].
Brau, ACS ;
Hedlund, LW ;
Johnson, GA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (01) :31-38
[5]   Fiber-optic stethoscope: A cardiac monitoring and gating system for magnetic resonance microscopy [J].
Brau, ACS ;
Wheeler, CT ;
Hedlund, LW ;
Johnson, GA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :314-321
[6]   SUSCEPTIBILITY-LIMITED RESOLUTION IN NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY [J].
CALLAGHAN, PT .
JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (02) :304-318
[7]   DIFFUSION-LIMITED RESOLUTION IN NUCLEAR MAGNETIC-RESONANCE MICROSCOPY [J].
CALLAGHAN, PT ;
ECCLES, CD .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01) :1-8
[8]   SENSITIVITY AND RESOLUTION IN NMR IMAGING [J].
CALLAGHAN, PT ;
ECCLES, CD .
JOURNAL OF MAGNETIC RESONANCE, 1987, 71 (03) :426-445
[9]   Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields [J].
Cassidy, PJ ;
Schneider, JE ;
Grieve, SM ;
Lygate, C ;
Neubauer, S ;
Clarke, K .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) :229-237
[10]   Noninvasive in vivo high-resolution magnetic resonance imaging of atherosclerotic lesions in genetically engineered mice [J].
Fayad, ZA ;
Fallon, JT ;
Shinnar, M ;
Wehrli, S ;
Dansky, HM ;
Poon, M ;
Badimon, JJ ;
Charlton, SA ;
Fisher, EA ;
Breslow, JL ;
Fuster, V .
CIRCULATION, 1998, 98 (15) :1541-1547