Identification and quantification of 8,5′-cycle-2′-deoxyadenosine in DNA by liquid chromatography/mass spectrometry

被引:77
作者
Dizdaroglu, M
Jaruga, P
Rodriguez, H
机构
[1] NIST, Chem Sci & Technol Lab, Gaithersburg, MD 20899 USA
[2] Ludwik Rydygier Med Univ, Dept Clin Biochem, Bydgoszcz, Poland
关键词
-8,5 '-cyclo-purine nucleosides; mass spectrometry; nucleotide-excision repair; oxidative DNA damage; free radicals;
D O I
10.1016/S0891-5849(01)00464-6
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Recent studies suggested that 8,5'-cyclo-2' -deoxyadenosine may play a role in diseases with defective nucleotide-excision repair. This compound is one of the major lesions, which is formed in DNA by hydroxyl radical attack on the sugar moiety of 2'-deoxyadenosine. It is likely to be repaired by nucleotide-excision repair rather than by base-excision repair because of a covalent bond between the sugar and base moieties. We studied the measurement of 8,5'-cyclo-2'-deoxyadenosine in DNA by liquid chromatography/isotope-dilution mass spectrometry. A methodology was developed for the analysis of 8,5'-cyclo-2'-deoxyadenosine by liquid chromatography in DNA hydrolyzed to nucleosides by a combination of four enzymes, i.e., DNase I, phosphodiesterases I and II, and alkaline phosphatase. Detection by mass spectrometry was performed using atmospheric pressure ionization-electrospray process in the positive ionization mode. Results showed that liquid chromatography/isotope-dilution mass spectrometry is well suited for identification and quantification of 8,5'-cyclo-2'-deoxyadenosine in DNA. Both (5'R)- and (5'S)-diastereomers of 8,5'-cyclo-2'-deoxyadenosine were detected. The level of sensitivity of liquid chromatography/mass spectrometry with selected-ion monitoring amounted to 2 fmol of this compound on the column. The yield of 8,5'-cyclo-2'-deoxyadenosine was measured in DNA in aqueous solution exposed to ionizing radiation at doses from 2.5 to 80 Gray. Gas chromatography/mass spectrometry was also used to measure this compound in DNA. Both techniques yielded similar results. The yield of 8,5'-cyclo-2'-deoxyadenosine was comparable to the yields of some of the other major modified bases in DNA, which were measured using gas chromatography/mass spectrometry. The measurement of 8,5'-cyclo-2'-deoxyadenosine by Liquid chromatography/mass spectrometry may contribute to the understanding of its biological properties and its role in diseases with defective nucleotide-excision repair. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:774 / 784
页数:11
相关论文
共 42 条