Bone-to-implant contact of orthodontic implants in humans subjected to horizontal loading

被引:89
作者
Wehrbein, H
Merz, BR [1 ]
Hammerle, CHF
Lang, NP
机构
[1] Inst Straumann AG, CH-4437 Waldenburg, Switzerland
[2] Free Univ Brussels, Clin Orthodont, B-1050 Brussels, Belgium
[3] Univ Bern, Dept Periodontol & Fixed Prosthodont, CH-3012 Bern, Switzerland
关键词
orthodontics; palatal implant; orthosystem; histomorphometry; implantation; anchorage;
D O I
10.1034/j.1600-0501.1998.090509.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Implant-based anchorage in orthodontics is increasingly obtaining significance. in this study, implants were temporarily inserted into the mid-palatal and the mandibular retromolar areas in humans for orthodontic anchorage. Histological analysis of the implant-bone interface was performed following the retrieval of implants which were subjected to prolonged oblique orthodontic loading. The results of the histomorphometric evaluation indicated that all the implants serving for orthodontic anchorage were well integrated into the bone despite the prolonged application of the orthodontic loading. Hence, it may be concluded that small-size, one-part transmucosal implants with a self-tapping thread and an SLA surface seemed to provide adequate anchorage for orthodontic therapy. Furthermore, the successful integration and the subsequent oblique loading of these orthodontic implants provide evidence that continuous forces in the order of magnitude of 2-6 N are compatible with the maintenance of osseointegration.
引用
收藏
页码:348 / 353
页数:6
相关论文
共 17 条
[1]  
[Anonymous], 1992, INF ORTHOD KIEFEROR
[2]   INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS [J].
BUSER, D ;
SCHENK, RK ;
STEINEMANN, S ;
FIORELLINI, JP ;
FOX, CH ;
STICH, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :889-902
[3]  
BUSER D, 1998, IN PRESS J BIOMEDICA
[4]   Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: Radiographic results [J].
Cochran, DL ;
Nummikoski, PV ;
Higginbottom, FL ;
Hermann, JS ;
Makins, SR ;
Buser, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :240-252
[5]  
Diedrich P, 1993, Fortschr Kieferorthop, V54, P156, DOI 10.1007/BF02171574
[6]  
Donath K., 1988, PRAPARATOR, V34, P197
[7]   SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE [J].
GUNDERSEN, HJG ;
BENDTSEN, TF ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (05) :379-394
[8]  
JAMES RA, 1973, J ORAL IMPLANTOL, V4, P294
[9]   ULTRASTRUCTURAL-STUDY OF EPITHELIAL-CELL ATTACHMENT TO IMPLANT MATERIALS [J].
JANSEN, JA ;
DEWIJN, JR ;
WOLTERSLUTGERHORST, JML ;
VANMULLEM, PJ .
JOURNAL OF DENTAL RESEARCH, 1985, 64 (06) :891-896
[10]  
ROBERTS WE, 1989, ANGLE ORTHOD, V59, P247