A cement spacer for two-stage revision of infected implants of the hip joint

被引:95
作者
Leunig, M [1 ]
Chosa, E [1 ]
Speck, M [1 ]
Ganz, R [1 ]
机构
[1] Univ Bern, Inselspital, Dept Orthopaed Surg, CH-3010 Bern, Switzerland
关键词
D O I
10.1007/s002640050244
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report the technical details and clinical results of twelve patients who had deep infections of implants in the hip joint and were treated by two-stage revision, using a gentamicin-loaded, hand-moulded cement spacer inserted for the period between resection and reimplantation arthroplasty. During management with the spacer usually for 4 months, patients were almost free of pain and mobile with good beg control, spending 2/3 of the treatment period at home. Six of twelve spacers failed locally due to dislocation [5] or cement fracture [1], and more than two further episodes of surgery were required in 3 patients. Problems with dislocation of the spacer were significantly higher when the head to neck offset was backing (P < 0.05) or when anchorage in the femoral shaft was poor. Nevertheless, infection after reimplantation arthroplasty did not occur by the rime of follow-up (2.2 years). Based on these data, we consider that the use of the cement spacer is a promising approach to the treatment of complicated infections of the hip joint.
引用
收藏
页码:209 / 214
页数:6
相关论文
共 33 条
[1]  
ABENDSCHEIN W, 1992, ORTHOPEDICS, V15, P228
[2]  
[Anonymous], CLIN ORTHOPAEDICS
[3]   OUTCOME OF THE INFECTED HIP-ARTHROPLASTY - A RETROSPECTIVE STUDY OF 36 PATIENTS [J].
ANTTIPOIKA, I ;
SANTAVIRTA, S ;
KONTTINEN, YT ;
HONKANEN, V .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (06) :670-675
[4]  
BALDERSTON RA, 1987, CLIN ORTHOP RELAT R, V221, P231
[5]  
BITTAR ES, 1982, CLIN ORTHOP RELAT R, V170, P83
[6]  
BOOTH RE, 1989, CLIN ORTHOP RELAT R, V248, P57
[7]   A 6-YEAR FOLLOW-UP OF INFECTED TOTAL HIP REPLACEMENTS MANAGED BY GIRDLESTONES ARTHROPLASTY [J].
BOURNE, RB ;
HUNTER, GA ;
RORABECK, CH ;
MACNAB, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (03) :340-343
[8]   MANAGEMENT OF DEEP INFECTION OF TOTAL HIP-REPLACEMENT [J].
BUCHHOLZ, HW ;
ELSON, RA ;
ENGELBRECHT, E ;
LODENKAMPER, H ;
ROTTGER, J ;
SIEGEL, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1981, 63 (03) :342-353
[9]   FAILURE OF BIPOLAR HIP-ARTHROPLASTY SECONDARY TO RETAINED ANTIBIOTIC-IMPREGNATED POLYMETHYLMETHACRYLATE BEADS - A CASE-REPORT [J].
CALHOUN, J ;
DAUM, W ;
MADER, JT ;
KOULISIS, C ;
EVANS, EB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (08) :1246-1248
[10]  
COLYER RA, 1994, CLIN ORTHOP RELAT R, P75