We examined 49 coronary stents in 33 patients after angiographically guided optimization of the deployment by intracoronary ultrasound, and compared the findings of a conventional 2-dimensional analysis approach with the results obtained from an automatic lumen recognition provided by a 3-dimensional reconstruction system, The automatic lumen analysis demonstrated that only 15 stents (31%) fulfilled defined ultrasound criteria of adequate stent deployment, and that 5 of these cases were missed by the conventional approach, which systematically overestimated the dimensions of the minimal stent lumen.
引用
收藏
页码:761 / &
页数:5
相关论文
共 9 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [3] Di Mario C, 1992, J Am Soc Echocardiogr, V5, P135
  • [4] DIMARIO C, 1995, BRIT HEART J, V73, P26
  • [5] INVIVO VALIDATION OF ONLINE AND OFF-LINE GEOMETRIC CORONARY MEASUREMENTS USING INSERTION OF STENOSIS PHANTOMS IN PORCINE CORONARY-ARTERIES
    HAASE, J
    DIMARIO, C
    SLAGER, CJ
    VANDERGIESSEN, WJ
    DENBOER, A
    DEFEYTER, PJ
    REIBER, JHC
    VERDOUW, PD
    SERRUYS, PW
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 27 (01): : 16 - 27
  • [6] INTRACORONARY ULTRASOUND IMAGING - INTRAOBSERVER AND INTEROBSERVER VARIABILITY OF MORPHOMETRIC MEASUREMENTS
    HAUSMANN, D
    LUNDKVIST, AJS
    FRIEDRICH, GJ
    MULLEN, WL
    FITZGERALD, PJ
    YOCK, PG
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (04) : 674 - 680
  • [7] THE SAFETY OF INTRACORONARY ULTRASOUND - A MULTICENTER SURVEY OF 2207 EXAMINATIONS
    HAUSMANN, D
    ERBEL, R
    ALIBELLICHEMARIN, MJ
    BOKSCH, W
    CARACCIOLO, E
    COHN, JM
    CULP, SC
    DANIEL, WG
    DESCHEERDER, I
    DIMARIO, C
    FERGUSON, JJ
    FITZGERALD, PJ
    FRIEDRICH, G
    GE, JB
    GORGE, G
    HANRATH, P
    HODGSON, JM
    ISNER, JM
    JAIN, S
    MAIERRUDOLPH, W
    MOONEY, M
    MOSES, JW
    MUDRA, H
    PINTO, FJ
    SMALLING, RW
    TALLEY, JD
    TOBIS, JM
    WALTER, PD
    WEIDINGER, F
    WERNER, GS
    YEUNG, AC
    YOCK, PG
    [J]. CIRCULATION, 1995, 91 (03) : 623 - 630
  • [8] HAUSMANN D, 1994, J AM COLL CARDIOL, V23, pA174
  • [9] IMPACT OF PREINTERVENTION INTRAVASCULAR ULTRASOUND IMAGING ON TRANSCATHETER TREATMENT STRATEGIES IN CORONARY-ARTERY DISEASE
    MINTZ, GS
    PICHARD, AD
    KOVACH, JA
    KENT, KM
    SATLER, LF
    JAVIER, SP
    POPMA, JJ
    LEON, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (07) : 423 - 430