Measurement and calculation of the spatial and spectral distribution of wavelength shifter radiation at BESSY

被引:10
作者
Thornagel, R
Fliegauf, R
Klein, R
Scholze, F
Ulm, G
机构
[1] Phys.-Technische Bundesanstalt, 10587 Berlin
关键词
D O I
10.1063/1.1146836
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Calculable synchrotron radiation (SR) from BESSY dipole magnets has been used by PTB for radiometry from the visible to the soft x-ray region with very low uncertainties for many years. The use of wavelength shifter (WLS) radiation bears the potential of extending the usable spectral range for radiometry with calculable SR to higher photon energies. Initial investigations on the feasibility of this approach have been performed: an energy dispersive high-purity germanium detector (HPGe) was used to characterize the radiation of the new BESSY WLS with a magnetic field of B=3.2 T The HPGe detector has previously been calibrated and so the absolute spectral photon flux could be determined. The measured spectral photon flux was then compared to calculations and good agreement was found in the order of +/-5%. Although this is to our knowledge the best agreement demonstrated so far for an absolute comparison of measured WLS radiation to calculations, further improvements are needed for a future radiometric use of WLS radiation. This will be discussed. (C) 1996 American Institute of Physics.
引用
收藏
页码:653 / 657
页数:5
相关论文
共 9 条
[1]   DETERMINATION OF PHOTON-EMISSION PROBABILITIES OF RADIONUCLIDES USING A SI(LI) DETECTOR CALIBRATED BY THE PRIMARY STANDARD SOURCE, BESSY [J].
ARNOLD, D ;
ULM, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2) :43-48
[2]   ELECTRON STORAGE RING BESSY AS A SOURCE OF CALCULABLE SPECTRAL PHOTON FLUX IN THE X-RAY REGION [J].
ARNOLD, D ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1539-1542
[3]   A BEAM LINE FOR RADIANT POWER MEASUREMENTS OF VACUUM ULTRAVIOLET AND ULTRAVIOLET SOURCES IN THE WAVELENGTH RANGE 40-400-NM [J].
HOLLANDT, J ;
JANS, W ;
KUHNE, M ;
LINDENLAUF, F ;
WENDE, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1278-1281
[4]  
KRAMER D, 1992, BESSY ANN REPORT, P446
[5]   ESTABLISHMENT OF A SPECTRAL IRRADIANCE SCALE IN THE VISIBLE AND NEAR-INFRARED USING THE ELECTRON STORAGE RING BESSY [J].
RIEHLE, F ;
WENDE, B .
METROLOGIA, 1986, 22 (02) :75-85
[6]   CHARACTERIZATION OF A WINDOWLESS SI(LI) DETECTOR IN THE PHOTON ENERGY-RANGE 0.1-5 KEV [J].
SCHOLZE, F ;
ULM, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2) :49-54
[7]   ON THE CLASSICAL RADIATION OF ACCELERATED ELECTRONS [J].
SCHWINGER, J .
PHYSICAL REVIEW, 1949, 75 (12) :1912-1925
[8]  
THORNAGEL R, 1995, IN PRESS METROLOGIA, V32
[9]   MEASURING DEVICES AT BESSY FOR STORED BEAM CURRENTS RANGING FROM 0.8 PA TO 1 A [J].
ULM, G ;
HANSELZIEGLER, W ;
BERNSTORFF, S ;
WOLF, FP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1752-1755