Development and evaluation of an adult use-of-time instrument with an energy expenditure focus

被引:62
作者
Gomersall, Sjaan R. [1 ]
Olds, Tim S. [2 ]
Ridley, Kate [3 ]
机构
[1] Univ S Australia, Div Hlth Sci, Hlth & Use Time HUT Grp, Adelaide, SA 5001, Australia
[2] Univ S Australia, Sansom Inst Hlth Res, Hlth & Use Time HUT Grp, Adelaide, SA 5001, Australia
[3] Flinders Univ S Australia, Sch Educ, Adelaide, SA 5001, Australia
关键词
Physical activity; Questionnaires; Epidemiological methods; Reproducibility of results; PHYSICAL-ACTIVITY; RELIABILITY; QUESTIONNAIRE; VALIDATION; VALIDITY;
D O I
10.1016/j.jsams.2010.08.006
中图分类号
G8 [体育];
学科分类号
040301 [体育人文社会学];
摘要
Measurement in behavioural epidemiology depends on high resolution and precise and accurate measures of the behaviour of interest. Few questionnaires in the adult population are able to simultaneously collect the multidimensional information that is emerging as being important in the relationship between behaviour and health. This project had two objectives: (1) to develop an adult version of the computer-delivered Multimedia Activity Recall for Children and Adolescents (MARCA), a 24-h activity recall instrument that can measure use-of-time and estimate energy expenditure and (2) to determine the test-retest reliability and convergent validity of the developed adult MARCA. Thirty-eight healthy subjects (mean +/- SD, 31.7 +/- 12.1 yr) completed two recalls of the adult MARCA within 24-h and accelerometer counts were measured on 30 of the subjects. Bland-Altman analysis and intraclass correlation coefficients (ICC) were used to quantify the test-retest reliability of the adult MARCA. Spearman rank correlation coefficients (rho) were used to quantify convergent validity of the adult MARCA compared to accelerometer counts. The test-retest reliability coefficients of the adult MARCA were high with intra-class coefficients ranging from 0.99 to 1.00. Moderate to strong validity was observed for physical activity level (PAL) (MET.min score of accelerometer wear time) and accelerometer counts per minute (rho = 0.72). The adult MARCA is a valid and reliable self-report measure of use-of-time and energy expenditure, capable of a wide variety of flexible use-of-time analyses related to a wide range of behaviours. (C) 2010 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 26 条
[1]
Validation of a new self-report instrument for measuring physical activity [J].
Aadahl, M ;
Jorgensen, T .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (07) :1196-1202
[2]
Compendium of Physical Activities: an update of activity codes and MET intensities [J].
Ainsworth, BE ;
Haskell, WL ;
Whitt, MC ;
Irwin, ML ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
Bassett, DR ;
Schmitz, KH ;
Emplaincourt, PO ;
Jacobs, DR ;
Leon, AS .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S498-S516
[3]
Life-change events and participation in physical activity: a systematic review [J].
Allender, Steven ;
Hutchinson, Lauren ;
Foster, Charles .
HEALTH PROMOTION INTERNATIONAL, 2008, 23 (02) :160-172
[4]
BIDDLE S, 2003, J R SOC PROMO HEALTH, V124, P55
[5]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]
A METHOD TO ASSESS ENERGY-EXPENDITURE IN CHILDREN AND ADULTS [J].
BOUCHARD, C ;
TREMBLAY, A ;
LEBLANC, C ;
LORTIE, G ;
SAVARD, R ;
THERIAULT, G .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1983, 37 (03) :461-467
[7]
Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[8]
CHEN C, 2009, J PHYS ACT HEALTH, P354
[9]
Fisher R. A., 1921, Metron, V1, P3
[10]
Breaks in sedentary time - Beneficial associations with metabolic risk [J].
Healy, Genevieve N. ;
Dunstan, David W. ;
Salmon, Jo ;
Cerin, Ester ;
Shaw, Jonathan E. ;
Zimmet, Paul Z. ;
Owen, Neville .
DIABETES CARE, 2008, 31 (04) :661-666