Penetration of particles into buildings and associated physical factors. Part I: Model development and computer simulations

被引:37
作者
Thornburg, J
Ensor, DS
Rodes, CE
Lawless, PA
Sparks, LE
Mosley, RB
机构
[1] Res Triangle Inst, Res Triangle Pk, NC 27709 USA
[2] US EPA, Natl Risk Management Res Lab, Res Triangle Pk, NC 27711 USA
关键词
D O I
10.1080/02786820119886
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The PM2.5 standard proposed by the U.S. Environmental Protection Agency (EPA) has stimulated research on the relationships between particulate matter concentrations and the exposures and subsequent health responses of sensitive subpopulations, such as the elderly. Since individuals in these subpopulations may spend more than 90% of their time indoors, understanding the relationship between outdoor particle concentrations and those found in indoor microenvironments is critical. This research resulted in a time-dependent indoor air quality model incorporating all potential particle sources and loss mechanisms. Monte Carlo simulations of the model identified the mechanisms, such as particle loss during penetration through the building envelope, that modify the outdoor particle size distribution during transport into the interior of a building, calculated indoor-to-outdoor (I/O) concentration ratios, and estimated penetration factors as a function of particle size. Indoor particle generation and transport of outdoor particles through the HVAC system were the most important contributors to the indoor concentration in residential and commercial buildings, respectively. The most significant removal mechanisms included ventilation through and particle removal by the HVAC filter if an HVAC system was present, or particle deposition on indoor surfaces if an HVAC system was not present. The modeled I/O concentration ratios varied between 0.05 and 0.5, depending on particle size and type of ventilation system, and agreed well with published experimental results, Penetration factors less than unity were calculated for particles with aerodynamic diameters larger than 0.2 mum if the air exchange rate and steady-state I/O concentration ratio were correlated during the simulations. An additional correlation between the air exchange rate and particle deposition velocity is required if penetration factors less than unity are to be modeled for particles with aerodynamic diameters smaller than 0.2 mum. These results support the possibility that appropriate experimental studies will yield penetration factors less than unity.
引用
收藏
页码:284 / 296
页数:13
相关论文
共 26 条
[1]   INDOOR-OUTDOOR RELATIONSHIPS FOR AIRBORNE PARTICULATE MATTER OF OUTDOOR ORIGIN [J].
ALZONA, J ;
COHEN, BL ;
RUDOLPH, H ;
JOW, HN ;
FROHLIGER, JO .
ATMOSPHERIC ENVIRONMENT, 1979, 13 (01) :55-60
[2]  
[Anonymous], 1997, Federal Register Volume 62 N. Prescription Drug Products. Levothyroxine Sodium: From the Federal Register Online via the Government Publishing Office
[3]  
*ASHRAE, 1996, HEAT VENT AIR COND S
[4]  
AUSTIN BS, 1992, ENVIRON SCI TECHNOL, V26, P851
[5]   TURBULENT DEPOSITION AND GRAVITATIONAL SEDIMENTATION OF AN AEROSOL IN A VESSEL OF ARBITRARY SHAPE [J].
CRUMP, JG ;
SEINFELD, JH .
JOURNAL OF AEROSOL SCIENCE, 1981, 12 (05) :405-415
[6]   INDOOR-OUTDOOR RELATIONSHIPS OF RESPIRABLE SULFATES AND PARTICLES [J].
DOCKERY, DW ;
SPENGLER, JD .
ATMOSPHERIC ENVIRONMENT, 1981, 15 (03) :335-343
[7]   Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios [J].
Fogh, CL ;
Byrne, MA ;
Roed, J ;
Goddard, AJH .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (15) :2193-2203
[8]   Modeling indoor air concentrations near emission sources in imperfectly mixed rooms [J].
Furtaw, EJ ;
Pandian, MD ;
Nelson, DR ;
Behar, JV .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1996, 46 (09) :861-868
[9]   FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS [J].
HANLEY, JT ;
ENSOR, DS ;
SMITH, DD ;
SPARKS, LE .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (03) :169-178
[10]  
Hinds W.C., 1982, Aerosol Technology