Long-term survival of VDD pacing

被引:14
作者
Chamberlain-Webber, R [1 ]
Barnes, E [1 ]
Papouchado, M [1 ]
Crick, JP [1 ]
机构
[1] Univ Bristol, Bristol Royal Infirm, Dept Cardiol, Bristol BS2 8HW, Avon, England
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 11期
关键词
VDD pacing; follow-up; mode change;
D O I
10.1111/j.1540-8159.1998.tb01161.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
All patients with VDD systems implanted at a tertiary pacing center were identified from a computer database and data collected on pacing indications, follow-up duration, rate response, reasons for programming changes, and implant P wave amplitudes. Results: 366 implants were identified for which complete data were available for 335 leads implanted in 316 patients. The mean follow-up period was 24.1 months, and age at implant was 73.5 +/- 11.8 years. During follow-up, IB patients died (6%) and 62 (19.6%) were followed elsewhere. Indications for pacing were complete heart block, 56.6%; intermittent AV block, 21.8%; postablation complete heart block, 5.4%; 2:1 AV block, 13%; and others, 3.2%. Two groups: no mode change (NMC, n = 280) and mode change (MC, n = 36) were identified. Reasons for reprogramming in the MC group were as follows: atrial sensing, 11; AF/atrial flutter, 18; chronotropic incompetence, 3; and others 4. Significantly more MC patients had rate response programmed ON (44.4% vs 22.1%, P < 0.05). No significant differences between the two groups were found in other variables, including male gender (55.5% vs 54.6%), length of follow-up (27.1 +/- 17.8 vs 23.8 +/- 20.6 months), age at last follow-up (72 +/- 12.3 vs 75.9 +/- 11.9 years), and P wave amplitude (1.7 +/- 0.9 vs 1.8 +/- 0.9mV). Conclusion: Reprogramming of VDD systems is infrequent. When necessary, it is usually prompted by atrial arrhythmias or failure of atrial sensing. When adequate atrial chronotropy has been verified, VDD is an acceptable alternative to DDD pacing and survives well over the long term.
引用
收藏
页码:2246 / 2248
页数:3
相关论文
共 7 条
[1]   ITALIAN MULTICENTER STUDY ON A SINGLE LEAD VDD PACING SYSTEM USING A NARROW ATRIAL DIPOLE SPACING [J].
ANTONIOLI, GE ;
ANSANI, L ;
BARBIERI, D ;
GUARDIGLI, G ;
PERCOCO, GF ;
TOSELLI, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1890-1893
[2]   EUROPEAN MULTICENTER PROSPECTIVE FOLLOW-UP-STUDY OF 1,002 IMPLANTS OF A SINGLE LEAD VDD PACING SYSTEM [J].
CRICK, JCP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1742-1744
[3]  
CURZIO G, 1985, CARDIAC PACING ELECT, P865
[4]   CLINICAL PROBLEMS IN ATRIAL SYNCHRONOUS VENTRICULAR INHIBITED PACING - A LONG-TERM FOLLOW-UP OF 54 PATIENTS [J].
KRISTENSSON, BE ;
KRUSE, I ;
RYDEN, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (04) :693-701
[5]   ATRIAL SYNCHRONOUS VENTRICULAR INHIBITED PACING (VDD) - AN UNDERUTILIZED MODE OF PACING [J].
MESSENGER, JC ;
GREENBERG, PS ;
WARREN, J ;
CASTELLANET, MJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (02) :392-398
[6]   AN IMPLANTABLE SYNCHRONOUS PACEMAKER FOR LONG TERM CORRECTION OF COMPLETE HEART BLOCK [J].
NATHAN, DA ;
CENTER, S ;
KELLER, W ;
WU, CY .
AMERICAN JOURNAL OF CARDIOLOGY, 1963, 11 (03) :362-&
[7]  
SUTTON R, 1992, EUR JCPE, V4, P225