The reliability of the functional independence measure: A quantitative review

被引:1032
作者
Ottenbacher, KJ
Hsu, YW
Granger, CV
Fiedler, RC
机构
[1] UNIV TEXAS,MED BRANCH,GALVESTON,TX 77550
[2] SUNY BUFFALO,BUFFALO,NY 14260
[3] NATL CHENG KUNG UNIV,TAINAN,TAIWAN
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1996年 / 77卷 / 12期
关键词
D O I
10.1016/S0003-9993(96)90184-7
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: The reliability of the Functional Independence Measure (FIMS(SM)) for adults was examined using procedures of meta-analysis. Data Sources: Eleven published studies reporting estimates of reliability for the FIM were located using computer searches of lndex Medicus, Psychological Abstracts, the Functional As sessment Information Service, and citation tracking. Study Selection: Studies were identified and coded based on type of reliability (interrater, test-retest, or equivalence), method of data analysis, size of sample, and training or experience of raters. Data Extraction: Information from the articles was coded by two independent raters. Interrater reliability for coding all elements included in the analysis ranged from .89 to 1.00. Data Synthesis: The 11 investigations included a total of 1,568 patients and produced 221 reliability coefficients. The majority of the reliability values (81%) were from interrater reliability studies, and the intraclass correlation coefficient (ICC) was the most commonly used statistical procedure to compute reliability. The reported reliability values were converted to a common correlation metric and aggregated across the 11 studies. The results revealed a median interrater reliability for the total FIM of .95 and median test-retest and equivalence reliability values of .95 and .92, respectively. The median reliability values for the six FIM subscales ranged from .95 for Self-Care to .78 for Social Cognition. For the individual FIM items, median reliability values varied from .90 for Toilet Transfer to .61 for Comprehension. Median and mean reliability coefficients for FIM motor items were generally higher than for items in the cognitive or communication subscales. Conclusions: Based on the 11 studies examined in this review the FIM demonstrated acceptable reliability across a wide variety of settings, raters, and patients. (C) 1996 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation .
引用
收藏
页码:1226 / 1232
页数:7
相关论文
共 41 条
[1]  
ADAMOVICH BLB, 1992, NEUROREHABILITATION, V2, P42
[2]  
[Anonymous], 1984, Assessing individuals: Psychological and educational tests and measurements
[3]  
Brosseau L, 1994, CLIN REHABIL, V8, P107, DOI DOI 10.1177/026921559400800203
[4]  
Brosseau L.Wolfson.C., 1994, Clinical Rehabilitation, V8, P107, DOI [10.1177/026921559400800203, DOI 10.1177/026921559400800203]
[5]   A METHOD FOR ASSESSING THE QUALITY OF A RANDOMIZED CONTROL TRIAL [J].
CHALMERS, TC ;
SMITH, H ;
BLACKBURN, B ;
SILVERMAN, B ;
SCHROEDER, B ;
REITMAN, D ;
AMBROZ, A .
CONTROLLED CLINICAL TRIALS, 1981, 2 (01) :31-49
[6]  
Chau N, 1994, Disabil Rehabil, V16, P63
[7]  
Cooper H., 1989, Integrating research: A guide for literature review
[8]  
COOPER HM, 1979, J PERS SOC PSYCHOL, V37, P131
[9]  
FISHER RA, 1925, STAT MEHTODS RES WOR
[10]   EQUIVALENCE OF WEIGHTED KAPPA AND INTRACLASS CORRELATION COEFFICIENT AS MEASURES OF RELIABILITY [J].
FLEISS, JL ;
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1973, 33 (03) :613-619