The effect of heliox on nebulizer function using a β-agonist bronchodilator

被引:81
作者
Hess, DR
Acosta, FL
Ritz, RH
Kacmarek, RM
Camargo, CA
机构
[1] Massachusetts Gen Hosp, Dept Resp Care, Channing Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Emergency Med, Channing Lab, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Dept Med, Brigham & Womens Hosp, Boston, MA USA
关键词
asthma; bronchodilator administration; equipment design; helium/oxygen gas mixture; inhalation aerosols; nebulizers; particle size;
D O I
10.1378/chest.115.1.184
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate nebulizer performance when heliox was used to power the nebuliser, Methods: Conventional and continuous nebulizer designs were evaluated. The conventional nebulizer was used with 5 mg albuterol and flows of 8 L/min air; 8 L/min heliox and 11 L/min heliox; it was also used with In mg albuterol and a heliox flow of 8 L/min. The continuous nebulizer was set to deliver 10 mg of albuterol over 40 min at flows of 2 L/min air, 2 L/min heliox and 3 L/min heliox; it was also used with 20 lug albuterol and a heliox flow of 2 L/min, A cotton plug at die nebulizer mouthpiece was used to trap aerosol during simulated spontaneous breathing. The amount of albuterol deposited on the cotton plug was determined spectrophotometrically. Particle size was determined using an 11-stage cascade impactor. Results: For both nebulizer was, particle size and inhaled mass of albuterol decreased significantly (p < 0.001) when the nebulizer nas powered with heliox rather than air. When powered with heliox, the reduction in inhaled mass of albuterol was less for the conventional nebulizer (16%) than the continuous nebulizer (67%). The nebulization time, however, was more than twofold greater with heliox (p < 0,001), Increasing the flow of heliox increased the particle size (p < 0.05), inhaled mass of albuterol (p < 0.05), and inhaled mass of particles 1 to 5 mu m (p < 0.05) to levels similar to powering the nebulizer with air at the lower flow. Increasing the albuterol concentration in the nebulizer and using the lower heliox flow increased the inhaled mass of albuterol (p < 0.05) while maintaining the smaller particle size pl produced with that flow. Conclusions: The use of hellos to power a nebulizer affects both the inhaled mass of medication and the size of the aerosol particles, The flow to power the nebulizer should be increased when heliox is used.
引用
收藏
页码:184 / 189
页数:6
相关论文
共 24 条
[1]   DISPOSABLE JET NEBULIZERS - HOW RELIABLE ARE THEY [J].
ALVINE, GF ;
RODGERS, P ;
FITZSIMMONS, KM ;
AHRENS, RC .
CHEST, 1992, 101 (02) :316-319
[2]   DEPOSITION IN MAN OF PARTICLES INHALED IN AIR OR HELIUM-OXYGEN AT DIFFERENT FLOW-RATES [J].
ANDERSON, M ;
SVARTENGREN, M ;
PHILIPSON, K ;
CAMNER, P .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1990, 3 (03) :209-216
[3]   DEPOSITION IN ASTHMATICS OF PARTICLES INHALED IN AIR OR IN HELIUM-OXYGEN [J].
ANDERSON, M ;
SVARTENGREN, M ;
BYLIN, G ;
PHILIPSON, K ;
CAMNER, P .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (03) :524-528
[4]   Evaluation of heliox in children hospitalized with acute severe asthma - A randomized crossover trial [J].
Carter, ER ;
Webb, CR ;
Moffitt, CDR .
CHEST, 1996, 109 (05) :1256-1261
[5]  
CHIPPS B E, 1990, Pediatric Asthma Allergy and Immunology, V4, P271, DOI 10.1089/pai.1990.4.271
[6]   EFFECT OF LUNG AIRWAY BRANCHING PATTERN AND GAS-COMPOSITION ON PARTICLE DEPOSITION .2. EXPERIMENTAL STUDIES IN HUMAN AND CANINE LUNGS [J].
ESCH, JL ;
SPEKTOR, DM ;
LIPPMANN, M .
EXPERIMENTAL LUNG RESEARCH, 1988, 14 (03) :321-348
[7]   Medication nebulizer performance - Effects of diluent volume, nebulizer flow, and nebulizer brand [J].
Hess, D ;
Fisher, D ;
Williams, P ;
Pooler, S ;
Kacmarek, RM .
CHEST, 1996, 110 (02) :498-&
[8]  
HESS DR, 1995, RESPIRATORY CARE EQU
[9]   HELIOX THERAPY IN ACUTE SEVERE ASTHMA [J].
KASS, JE ;
CASTRIOTTA, RJ .
CHEST, 1995, 107 (03) :757-760
[10]  
KUDUKIS T, 1996, J PEDIATR, V130, P217