Neoplastic extension across pulmonary fissures: Value of spiral computed tomography and multiplanar reformations

被引:10
作者
Storto, ML [1 ]
Ciccotosto, C [1 ]
Guidotti, A [1 ]
Merlino, B [1 ]
Patea, RL [1 ]
Bonomo, L [1 ]
机构
[1] Univ Chieti, Osped SS Annunziata, Dept Radiol, I-66100 Chieti, Italy
关键词
lung neoplasms; computed tomography; pleura; helical technology;
D O I
10.1097/00005382-199807000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the value of spiral computed tomography (CT) with multiplanar reformations for detection of neoplastic extension across pulmonary fissures, 51 patients with a lung neoplasm near a fissure underwent spiral CT, followed by multiplanar reformations, and spaced thin-section CT scans through the area of contact between tumor and fissure. The CT studies were evaluated for visibility of fissures and their relationship to the tumor. Imaging findings were compared with surgical results in 31 patients who underwent thoracotomy. Visibility of fissures on multiplanar reformations was either good or acceptable in 47 (92.2%) patients, and poor in four. Surgical findings of neoplastic extension across the major or the minor fissure were present in seven and eight patients, respectively. Thin-section CT scans were 83.3% sensitive in assessing neoplastic involvement of the major fissure, axial CT scans were 57.1% sensitive, and spiral CT multiplanar images were 100% sensitive. In the evaluation of the minor fissure, thin-section CT and axial spiral CT scans were considered inconclusive in six patients whereas multiplanar reformations enabled correct assessment of the fissure/neoplasm relationship in all but one patient. Spiral CT multiplanar images are accurate for detection of transfissural neoplastic extension, and are superior to axial CT scans for evaluation of rumors near the minor fissure.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 20 条
[1]   ANATOMY OF THE MINOR FISSURE - EVALUATION WITH THIN-SECTION CT [J].
BERKMEN, YM ;
AUH, YH ;
DAVIS, SD ;
KAZAM, E .
RADIOLOGY, 1989, 170 (03) :647-651
[2]   ABNORMALITIES OF THE DIAPHRAGM AND ADJACENT STRUCTURES - FINDINGS ON MULTIPLANAR SPIRAL CT SCANS [J].
BRINK, JA ;
HEIKEN, JP ;
SEMENKOVICH, J ;
TEEFEY, SA ;
MCCLENNAN, BL ;
SAGEL, SS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :307-310
[3]  
Chasen M H, 1986, Radiographics, V6, P793
[4]   ASSESSMENT OF THE THORACIC AORTA BY SPIRAL CT [J].
COSTELLO, P ;
ECKER, CP ;
TELLO, R ;
HARTNELL, GG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (05) :1127-1130
[5]   SPIRAL CT OF THE THORAX WITH REDUCED VOLUME OF CONTRAST MATERIAL - A COMPARATIVE-STUDY [J].
COSTELLO, P ;
DUPUY, DE ;
ECKER, CP ;
TELLO, R .
RADIOLOGY, 1992, 183 (03) :663-666
[6]   THORACIC HELICAL CT [J].
COSTELLO, P .
RADIOGRAPHICS, 1994, 14 (04) :913-918
[7]   COMPUTED-TOMOGRAPHY OF THE PULMONARY FISSURES - NORMAL ANATOMY [J].
FRIJA, J ;
SCHMIT, P ;
KATZ, M ;
VADROT, D ;
LAVALJEANTET, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (06) :1069-1074
[8]   ANATOMY OF THE MAJOR FISSURE - EVALUATION WITH STANDARD AND THIN-SECTION CT [J].
GLAZER, HS ;
ANDERSON, DJ ;
DICROCE, JJ ;
SOLOMON, SL ;
WILSON, BS ;
MOLINA, PL ;
SAGEL, SS .
RADIOLOGY, 1991, 180 (03) :839-844
[9]   VIDEO-ASSISTED THORACIC-SURGERY - THE CURRENT STATE-OF-THE-ART [J].
KAISER, LR ;
SHRAGER, JB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) :1111-1117
[10]  
Kuhlman J E, 1994, J Digit Imaging, V7, P42