MR colonography: How does air compare to water for colonic distention?

被引:45
作者
Ajaj, W
Lauenstein, TC
Pelster, G
Goehde, SC
Debatin, JF
Ruehm, SG
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Univ Hosp Essen, Dept Gastroenterol, D-45122 Essen, Germany
关键词
MR colonography; air; water; contrast agent; enema;
D O I
10.1002/jmri.10455
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prove the feasibility of air-distended magnetic resonance colonography (MRC) and compare it with water-based distention. Materials and Methods: In five volunteers, the colon was imaged twice: once after distending the colon with air and a second time after distending the colon with water. A total of 50 patients, who had been referred to colonoscopy for a suspected colorectal pathology were randomized into water-distention (N=25) and air-distention (N=25) groups. A contrast-enhanced T1-weighted three-dimensional volume interpolated breath-hold (VIBE) sequence was collected. Comparative analysis was based on qualitative ratings of image quality and bowel distention, as well as contrast-to-noise ratio (CNR) measurements for the colonic wall with respect to the colonic lumen. In addition, patient acceptance was evaluated. Results: Inflammatory changes and colorectal masses were correctly identified on MRC in eight patients each. One 4-mm polyp identified at colonoscopy was missed on water-distended MRC. There were no false positive findings. No significant differences were found between air- and water-distention regarding discomfort levels and image quality. The presence of air in the colonic lumen was not associated with susceptibility artifacts. CNR of the contrast-enhanced colonic wall, as well as bowel distention, were superior on air-distended three-dimensional data sets. Conclusion: MRC can be performed using either water or air for colonic distention. Both techniques permit assessment of the colonic wall and identification of colorectal. masses. While discomfort levels are similar for both agents, MRC with air provides higher CNR and better colonic distention.
引用
收藏
页码:216 / 221
页数:6
相关论文
共 31 条
[1]  
Bremerich J, 2000, J MAGN RESON IMAGING, V11, P622, DOI 10.1002/1522-2586(200006)11:6<622::AID-JMRI8>3.0.CO
[2]  
2-0
[3]   Virtual colonoscopy: Imaging features with colonoscopic correlation [J].
Fenlon, HM ;
Clarke, PD ;
Ferrucci, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1303-1309
[4]   CT colonography: Potential pitfalls and problem-solving techniques [J].
Fletcher, JG ;
Johnson, CD ;
MacCarty, RL ;
Welch, TJ ;
Reed, JE ;
Hara, AK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1271-1278
[5]  
Hagspiel KD, 2000, MAGNET RESON MED, V44, P813, DOI 10.1002/1522-2594(200011)44:5<813::AID-MRM21>3.0.CO
[6]  
2-3
[7]  
Hara AK, 1997, GASTROENTEROLOGY, V112, pA575
[8]   T2*and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging [J].
Hatabu, H ;
Alsop, DC ;
Listerud, J ;
Bonnet, M ;
Gefter, WB .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 29 (03) :245-252
[9]   A comparison of air, CO2 and an air/CO2 mixture as insufflation agents for double contrast barium enema [J].
Holemans, JA ;
Matson, MB ;
Hughes, JA ;
Seed, P .
EUROPEAN RADIOLOGY, 1998, 8 (02) :274-276
[10]   MR colonography without colonic cleansing: A new strategy to improve patient acceptance [J].
Lauenstein, T ;
Holtmann, G ;
Schoenfelder, D ;
Bosk, S ;
Ruehm, SG ;
Debatin, JF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (04) :823-827