Evaluation of methods to detect and control nitrification inhibition with specific application to incinerator flue-gas scrubber water

被引:19
作者
Daigger, GT
Sadick, TE
机构
[1] CH2M Hill, Englewood, CO 80112 USA
[2] CH2M Hill, Newport News, VA USA
关键词
nitrification; inhibition; procedures; maximum specific growth rate; hydrogen cyanide; multiple-hearth incineration;
D O I
10.2175/106143098X123606
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two procedures for determining the maximum specific growth rate of nitrifying bacteria in the presence of inhibitors were evaluated. One procedure uses a population of nitrifying bacteria and a short-term (6-hour) batch assay to determine the impact of the test wastewater on the maximum specific growth rate of the nitrifiers. The difference in the specific nitrification rate for the subject population between a control and the test wastewater quantifies the effect of the constituents in the test wastewater on the nitrifier maximum specific growth rate. The second procedure uses batch fill-and-draw bioreactors operated under steady-state conditions to determine the minimum mean cell residence time for growth of the nitrifiers. The need to assess nitrification inhibition at two large municipal wastewater treatment plants provided the opportunity to evaluate these two procedures. Incineration of biosolids is practiced at both of these plants, and it was shown that in-plant recycle of the multiple-hearth flue-gas scrubber water can be inhibitory to nitrification. Results from extensive testing indicated that hydrocyanic acid (HCN), present in the scrubber water, is the probable inhibitor. Consistent results were obtained at both plants. They indicated that HCN concentrations on the order of 0.1 to 0.2 mg/L resulted in a reduction in the nitrifier maximum specific growth rate of approximately 50%. Treatment methods were evaluated at each plant and implemented. At one plant, aerobic biological treatment of the incinerator sidestream is being practiced. At the other facility, cyanide is thermally destroyed in afterburners before contact with the wet scrubbing system.
引用
收藏
页码:1248 / 1257
页数:10
相关论文
共 23 条
[1]  
[Anonymous], 1992, STAND METH EX WAT WA
[2]  
BARNARD JL, 1997, P 70 ANN WAT ENV FED, V1, P629
[3]  
BENEFIELD LD, 1982, PROCESS CHEM WATER W, P425
[4]  
BLUM DJW, 1991, RES J WATER POLLUT C, V63, P198
[5]  
DAIGGER GT, 1988, J WATER POLLUT CON F, V60, P1833
[6]  
GARMAN KR, 1996, P WAT ENV FED 69 ANN, V1, P625
[7]  
GAUDY AF, 1982, J WATER POLLUT CON F, V54, P153
[8]  
HARREMOES P, 1992, J IWEM, V6, P50
[9]   A GENERAL-MODEL FOR SINGLE-SLUDGE WASTE-WATER TREATMENT SYSTEMS [J].
HENZE, M ;
GRADY, CPL ;
GUJER, W ;
MARAIS, GVR ;
MATSUO, T .
WATER RESEARCH, 1987, 21 (05) :505-515
[10]  
HILL, 1991, NANESMOND PLANT SERV