Reliability of power output during intermittent high-intensity cycling

被引:34
作者
Capriotti, PV [1 ]
Sherman, WM [1 ]
Lamb, DR [1 ]
机构
[1] Ohio State Univ, Sch Phys Act & Educ Serv, Sport & Exercise Sect, Columbus, OH 43210 USA
关键词
exercise test; test reproducibility; peak power; mean power; coefficient of variation;
D O I
10.1097/00005768-199906000-00023
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: We determined the number of trials on consecutive days required to establish high reliability of an intermittent high-intensity cycling test in subjects unfamiliar with multiple-sprint exercise. We also examined the extent to which this reliability could be maintained for 6 d. Methods: Five untrained men performed a multiple-sprint test (10 x 7 s, with each sprint separated by 30 s) on each of four consecutive days (days 1-4), then rested for 6 d, and finally performed two additional tests on consecutive days (days 11 and 12). For statistical comparisons (analyses of variance), mean power outputs during sprints 8, 9, and 10 (MP8-10) on each test day were calculated for each of the 4th, 5th, and 6th seconds of the sprints, i.e., MP8-0(4th), MP8-10(5th), and MP8-10(6th). Peak power during each sprint was also examined. Results: For days 3 and 4, Values for MP8-10(4th), MP8-10(5th), and MP8-10(6th) were greater than on day 1 (P < 0.05). MP8-10(6th) on day 2 was also greater than on day 1 (P < 0.05). There were no differences in MP8-10 among days 2, 3, 4, 11, and 12. Also, peak power on day 1 was lower (P < 0.05) than peak power for all other days, which were not different from one another. The coefficients of variation (CV) for MP8-10 on day 3 versus day 4 were 3.3%, 2.5%, and 2.9% for MP8-10(4th), MP8-10(5th), and MP8-10(6th), respectively. The CV for MP8-10(4th), MP8-10(5th), and MP8-10(6th) on days 4, 11, and 12 ranged from 2.1 to 3.9%, with an overall mean of 3.1%. The greatest CV for MP8-10 was 5.2% for MP8-10(6th) on days 2 Versus 3 and 2 versus 4. The mean CV for peak power for all pairwise combinations of days 4, 11, and 12 was 2.8%. Conclusions: In conclusion, satisfactory reliability of intermittent cycling tests is achieved after two familiarization sessions identical to the tests, and that reliability can be maintained for 6 d.
引用
收藏
页码:913 / 915
页数:3
相关论文
共 9 条
[1]   BIOLOGICAL AND TECHNOLOGICAL VARIABILITY OF 3 ANAEROBIC ERGOMETER TESTS [J].
COGGAN, AR ;
COSTILL, DL .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1984, 5 (03) :142-145
[2]   ADAPTATIONS IN SKELETAL-MUSCLE FOLLOWING STRENGTH TRAINING [J].
COSTILL, DL ;
COYLE, EF ;
FINK, WF ;
LESMES, GR ;
WITZMANN, FA .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (01) :96-99
[3]  
Fitzsimmons M, 1993, AUST J SCI MED SPORT, V25, P82
[4]   Enzyme adaptations of human skeletal muscle during bicycle short-sprint training and detraining [J].
Linossier, MT ;
Dormois, D ;
Perier, C ;
Frey, J ;
Geyssant, A ;
Denis, C .
ACTA PHYSIOLOGICA SCANDINAVICA, 1997, 161 (04) :439-445
[5]   Muscle performance and enzymatic adaptations to sprint interval training [J].
MacDougall, JD ;
Hicks, AL ;
MacDonald, JR ;
McKelvie, RS ;
Green, HJ ;
Smith, KM .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (06) :2138-2142
[6]  
MORITANI T, 1979, AM J PHYS MED REHAB, V58, P115
[7]   DETERMINING THE VARIABILITY OF PERFORMANCE ON WINGATE ANAEROBIC TESTS IN CHILDREN AGED 6-12 YEARS [J].
NAUGHTON, G ;
CARLSON, J ;
FAIRWEATHER, I .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1992, 13 (07) :512-517
[8]   ANAEROBIC MUSCLE ENZYME CHANGES AFTER INTERVAL TRAINING [J].
ROBERTS, AD ;
BILLETER, R ;
HOWALD, H .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1982, 3 (01) :18-21
[9]   A CONSTANT-LOAD ERGOMETER FOR MEASURING PEAK POWER OUTPUT AND FATIGUE [J].
WILLIAMS, JH ;
BARNES, WS ;
SIGNORILE, JF .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (05) :2343-2348