Sequential magnetic resonance monitoring of pulmonary flow with endovascular stents placed across the pulmonary valve in growing swine

被引:42
作者
Kuehne, T
Saeed, M
Reddy, G
Akbari, H
Gleason, K
Turner, D
Teitel, D
Moore, P
Higgins, CB
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Div Pediat Cardiol, San Francisco, CA 94143 USA
关键词
magnetic resonance imaging; stents; pulmonary heart disease;
D O I
10.1161/hc4401.098472
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Patients with endovascular stent implantation for the treatment of right ventricular outflow tract obstruction are often left with incomplete relief of the obstruction and significant pulmonary regurgitation. A noninvasive and reproducible method for monitoring such patients is desirable. MRI in the presence of a stent, however, has to overcome the problem of potential metallic artifacts. Methods and Results-Under x-ray fluoroscopic guidance, endovascular nitinol stents were placed across the pulmonary valve in 6 young pigs to induce pulmonary regurgitation. Five additional pigs served as controls. Initial MRI was performed after 2 days (13.5 +/-1.8 kg) and follow-up after 3 months (32 +/-2.9 kg). Pulmonary flow volumes and regurgitant fraction were quantified by velocity-encoded cine (VEC) MRI through (VEC-TS) and distal to (VEC-DS) the stent. VEC-TS was compared with VEC-DS and volumetric measurements of left and right ventricular stroke volumes provided by cine MRI ("gold standard"). Antegrade and retrograde pulmonary flow volumes by VEC-TS were slightly but significantly less than those with VEC-DS and cine MRL Excellent correlations (r >0.97) for phasic pulmonary flow volumes as measured by VEC-TS and VEC-DS were shown. Pulmonary regurgitant fraction increased from 32.8 +/- 15% to 49.6 +/- 17% (P <0.05) over the course of 3 months with VEC-TS. Conclusions-MRI demonstrates the progression of pulmonary regurgitation in growing swine. VEC MRI has the ability to quantify pulmonary blood flow inside the lumen of nitinol stents. MRI appears to be ideally suited for monitoring patients with endovascular nitinol stents in the pulmonary artery or pulmonary valve position.
引用
收藏
页码:2363 / 2368
页数:6
相关论文
共 23 条
[1]   Transcatheter implantation of a bovine valve in pulmonary position - A lamb study [J].
Bonhoeffer, P ;
Boudjemline, Y ;
Saliba, Z ;
Hausse, AO ;
Aggoun, Y ;
Bonnet, D ;
Sidi, D ;
Kachaner, J .
CIRCULATION, 2000, 102 (07) :813-816
[2]   Early and intermediate-term complications of self-expanding stents limit its potential application in children with congenital heart disease [J].
Cheung, YF ;
Sanatani, S ;
Leung, MP ;
Human, DG ;
Chau, AKT ;
Culham, JAG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (04) :1007-1015
[3]   Arterial switch procedure for D-transposition of the great arteries:: Quantitative midterm evaluation of hemodynamic changes with cine MR imaging and phase-shift velocity mapping -: Initial experience [J].
Gutberlet, M ;
Boeckel, T ;
Hosten, N ;
Vogel, M ;
Kühne, T ;
Oellinger, H ;
Ehrenstein, T ;
Venz, S ;
Hetzer, R ;
Bein, G ;
Felix, R .
RADIOLOGY, 2000, 214 (02) :467-475
[4]  
HAACKE M, 1996, MAGNETIC RESONANCE I
[5]   QUANTIFICATION OF RIGHT-VENTRICULAR FUNCTION WITH MAGNETIC-RESONANCE-IMAGING IN CHILDREN WITH NORMAL HEARTS AND WITH CONGENITAL HEART-DISEASE [J].
HELBING, WA ;
REBERGEN, SA ;
MALIEPAARD, C ;
HANSEN, B ;
OTTENKAMP, J ;
REIBER, JHC ;
DEROOS, A .
AMERICAN HEART JOURNAL, 1995, 130 (04) :828-837
[6]   Clinical applications of cardiac magnetic resonance imaging after repair of tetralogy of Fallot [J].
Helbing, WA ;
de Roos, A .
PEDIATRIC CARDIOLOGY, 2000, 21 (01) :70-79
[7]   Plain and covered stent-grafts: In vitro evaluation of characteristics at three-dimensional MR angiography [J].
Hilfiker, PR ;
Quick, HH ;
Debatin, JF .
RADIOLOGY, 1999, 211 (03) :693-697
[8]   INTRAVASCULAR STENT PROSTHESIS FOR RIGHT VENTRICULAR OUTFLOW OBSTRUCTION [J].
HOSKING, MCK ;
BENSON, LN ;
NAKANISHI, T ;
BURROWS, PE ;
WILLIAMS, WG ;
FREEDOM, RM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :373-380
[9]  
Klemm T, 2000, J MAGN RESON IMAGING, V12, P606, DOI 10.1002/1522-2586(200010)12:4<606::AID-JMRI14>3.0.CO
[10]  
2-J