Evaluation of three smoke detector promotion programs

被引:31
作者
Shults, RA
Sacks, JJ
Briske, LA
Dickey, PH
Kinde, MR
Mallonee, S
Douglas, MR
机构
[1] Ctr Dis Control & Prevent, Natl Ctr Injury Prevent & Control, Atlanta, GA 30341 USA
[2] Minnesota Dept Hlth, Injury & Violence Prevent Unit, Ctr Hlth Promot, Minneapolis, MN 55440 USA
[3] Employment Secur Commiss N Carolina, Murphy, NC 28906 USA
[4] Oklahoma State Dept Hlth, Epidemiol Serv, Oklahoma City, OK 73117 USA
关键词
accident prevention; accident; home; burns; fires; program evaluation;
D O I
10.1016/S0749-3797(98)00071-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Context: Seventy percent of U.S. residential fire deaths occur in homes without a working smoke detector. To help prevent residential fire deaths, many programs have distributed or installed detectors in unprotected homes. Because persons receiving a detector may not install it and because detector batteries require annual replacement, the enduring effectiveness of these programs may be questioned. Objective: We evaluated the long-term functional status of smoke detectors distributed to high-risk households in eight areas of Minnesota, Cherokee County (North Carolina), and Oklahoma City (Oklahoma). Design: Cross-sectional. Setting: Home visits were made to check the detectors that were distributed 3 to 4 years earlier. Participants: Randomly selected households from the three detector promotion programs. Main Out-come Measure: At least one working smoke detector. Results: Participation rates ranged from 72% to 82%. The percentage of evaluation households with at least one working detector ranged from 58% in Oklahoma to 73% in North Carolina. In 76% of households with nonworking detectors, the batteries were either missing or disconnected. When batteries in nonworking detectors were replaced, 83% of the detectors regained function. Conclusions: Future programs should consider distributing detectors that do not require annual battery changes or find effective ways to ensure that batteries are routinely replaced. Programs should also provide each household with the number of detectors needed to meet the most current recommended standard of the National Fire Protection Agency. The evaluation's participation rates support the practicality of unannounced home visits to evaluate home injury prevention programs in high-risk groups.
引用
收藏
页码:165 / 171
页数:7
相关论文
共 21 条
[1]  
Douglas M R, 1998, Inj Prev, V4, P28
[2]  
*FED EM MAN AG, 1993, US FIR ADM PUBL
[3]  
FRANKEL LR, 1982, DEFINITION RESPONSE
[4]  
GORMAN RL, 1985, PEDIATRICS, V75, P14
[5]  
HALL JR, 1994, NATL FIR PROT ASS J, P36
[6]  
KARTER MJ, 1996, ASS J SEP, P52
[7]  
KISH L, 1965, SURVEY SAMPLING, P21
[8]  
KULENKAMP A, 1994, REACHING HARD REACH
[9]   Surveillance and prevention of residential-fire injuries [J].
Mallonee, S ;
Istre, GR ;
Rosenberg, M ;
ReddishDouglas, M ;
Jordan, F ;
Silverstein, P ;
Tunell, W .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (01) :27-31
[10]  
*NAT CTR HLTH STAT, HLTH PEOPL 2000 REV