Comparison of field performance of multiple soil moisture sensors in a semi-arid rangeland

被引:30
作者
Paige, Ginger B. [1 ]
Keefer, Timothy O. [2 ]
机构
[1] Univ Wyoming, Laramie, WY 82071 USA
[2] SW Watershed Res Ctr, USDA ARS, Tucson, AZ 85719 USA
来源
JOURNAL OF THE AMERICAN WATER RESOURCES ASSOCIATION | 2008年 / 44卷 / 01期
关键词
soil moisture; instrumentation; rangelands; capacitance probe; time domain reflectometry; infiltration model;
D O I
10.1111/j.1752-1688.2007.00142.x
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Automated electronic soil moisture sensors, such as time domain reflectometry (TDR) and capacitance probes are being used extensively to monitor and measure soil moisture in a variety of scientific and land management applications. These sensors are often used for a wide range of soil moisture applications such as drought forage prediction or validation of large-scale remote sensing instruments. The convergence of three different research projects facilitated the evaluation and comparison of three commercially available electronic soil moisture probes under field application conditions. The sensors are all installed in shallow soil profiles in a well instrumented small semi-arid shrub covered subwatershed in Southeastern Arizona. The sensors use either a TDR or a capacitance technique; both of which indirectly measure the soil dielectric constant to determine the soil moisture content. Sensors are evaluated over a range of conditions during three seasons comparing responses to natural wetting and drying sequences and using water balance and infiltration simulation models. Each of the sensors responded to the majority of precipitation events; however, they varied greatly in response time and magnitude from each other. Measured profile soil moisture storage compared better to water balance estimates when soil moisture in deeper layers was accounted for in the calculations. No distinct or consistent trend was detected when comparing the responses from the sensors or the infiltration model to individual precipitation events. The results underscore the need to understand how the sensors respond under field application and recognize the limitations of soil moisture sensors and the factors that can affect their accuracy in predicting soil moisture in situ.
引用
收藏
页码:121 / 135
页数:15
相关论文
共 40 条
[1]  
AMER SA, 1994, WATER RESOUR BULL, V30, P69
[2]  
Bosch DD, 2004, VADOSE ZONE J, V3, P1380
[3]  
*CAMPB SCI IC, 2004, TDR100 INSTR MAN
[4]   Field calibration of water content reflectometers [J].
Chandler, DG ;
Seyfried, M ;
Murdock, M ;
McNamara, JP .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2004, 68 (05) :1501-1507
[5]  
COSH MH, 2007, TEMPORAL PERSISTENCE
[6]  
Delta T Devices Ltd., 1999, THET PROB SOIL MOIST
[7]   Carbon dioxide fluxes in a semiarid environment with high carbonate soils [J].
Emmerich, WE .
AGRICULTURAL AND FOREST METEOROLOGY, 2003, 116 (1-2) :91-102
[8]   IMPACT OF SMALL-SCALE SPATIAL RAINFALL VARIABILITY ON RUNOFF MODELING [J].
FAURES, JM ;
GOODRICH, DC ;
WOOLHISER, DA ;
SOROOSHIAN, S .
JOURNAL OF HYDROLOGY, 1995, 173 (1-4) :309-326
[9]  
FREIMUND JR, 1992, THESIS U ARIZONA TUS
[10]  
Haan C.T., 1977, STAT METHODS HYDROLO