Capillary electrophoresis coupled to mass spectrometry to establish polypeptide patterns in dialysis fluids

被引:78
作者
Kaiser, T
Hermann, A
Kielstein, JT
Wittke, S
Bartel, S
Krebs, R
Hausadel, F
Hillmann, M
Golovko, I
Koester, P
Haller, H
Weissinger, EM
Fliser, D
Mischak, H
机构
[1] Mosaiques Diagnost & Therapeut AG, D-30625 Hannover, Germany
[2] Hannover Med Sch, Dept Internal Med, D-3000 Hannover, Germany
关键词
proteomics; dialysis; polypeptides; peptides;
D O I
10.1016/S0021-9673(03)00712-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Combination of capillary electrophoresis with mass spectrometry (CE-MS) allows generation of polypeptide patterns of body fluids. In a single CE-MS (45 min) run more than 600 polypeptides were analyzed in hemodialysis fluids obtained with different membranes (high-flux/low-flux). Larger polypeptides (M-r>10 000) were almost exclusively present in high-flux dialysates only, while in low-flux dialysates additional small polypeptides were detected. Comparison to the normal urine pattern yielded a surprisingly low consensus: a number of polypeptides present in urine were missing. We established a fast and sensitive technique, easily applicable to the monitoring of different modalities of dialyzers. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 171
页数:15
相关论文
共 35 条
[1]   Predictive value of cardiac troponin I and T for subsequent death in end-stage renal disease [J].
Apple, FS ;
Murakami, MM ;
Pearce, LA ;
Herzog, CA .
CIRCULATION, 2002, 106 (23) :2941-2945
[2]  
Clark WR, 2002, J AM SOC NEPHROL, V13, pS41
[3]   Automated LC-LC-MS-MS platform using binary ion-exchange and gradient reversed-phase chromatography for improved proteomic analyses [J].
Davis, MT ;
Beierle, J ;
Bures, ET ;
McGinley, MD ;
Mort, J ;
Robinson, JH ;
Spahr, CS ;
Yu, W ;
Luethy, R ;
Patterson, SD .
JOURNAL OF CHROMATOGRAPHY B, 2001, 752 (02) :281-291
[4]   Effect of dialysis dose and membrane flux in maintenance hemodialysis. [J].
Eknoyan, G ;
Beck, GJ ;
Cheung, AK ;
Daugirdas, JT ;
Greene, T ;
Kusek, JW ;
Allon, M ;
Bailey, J ;
Delmez, JA ;
Depner, TA ;
Dwyer, JT ;
Levey, AS ;
Levin, NW ;
Milford, E ;
Ornt, DB ;
Rocco, MV ;
Schulman, G ;
Schwab, SJ ;
Teehan, BP ;
Toto, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (25) :2010-2019
[5]   TRACE ANALYSIS OF PROTEINS BY CAPILLARY ZONE ELECTROPHORESIS WITH ON-COLUMN TRANSIENT ISOTACHOPHORETIC PRECONCENTRATION [J].
FORET, F ;
SZOKO, E ;
KARGER, BL .
ELECTROPHORESIS, 1993, 14 (5-6) :417-428
[6]  
Gerdemann A, 2000, CLIN NEPHROL, V54, P276
[7]  
Hampel DJ, 2001, J AM SOC NEPHROL, V12, P1026, DOI 10.1681/ASN.V1251026
[8]  
Hille JM, 2001, ELECTROPHORESIS, V22, P4035, DOI 10.1002/1522-2683(200111)22:19<4035::AID-ELPS4035>3.0.CO
[9]  
2-9
[10]  
Jungblut PR, 1999, ELECTROPHORESIS, V20, P2100