Repeatability and reproducibility of high concentration data in reversed-phase liquid chromatography I.: Overloaded band profiles on Kromasil-C18

被引:41
作者
Gritti, F
Guiochon, G
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN USA
关键词
adsorption isotherms; band profiles; frontal analysis; mathematical modeling; aniline; caffeine; phenol; propranolol; theophylline; ethylbenzene;
D O I
10.1016/S0021-9673(03)00685-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Single-component adsorption-isotherm data were acquired by frontal analysis (FA) for six low-molecular-mass compounds (phenol. aniline, caffeine, theophylline, ethylbenzene and propranolol) on one Kromasil-C-18 column, using water-methanol solutions (between 70:30 and 20:80, v/v) as the mobile phase. Propranolol data were also acquired using an acetate buffer (0.2 M) instead of water. The data were modeled for best agreement between calculated and experimental overloaded band profiles. The adsorption energy distribution was also derived and used for the selection of the best isotherm model. Widely different isotherm models were found to model best the data obtained for these compounds, convex upward (i.e. Langmuirian), convex downward (i.e. anti-Langmuirian), and S-shaped isotherms. Using the same sample size for all columns (loading factor, Lfsimilar or equal to10%), overloaded band profiles were recorded on four different columns packed with the same batch of Kromasil-C-18 and five other columns packed with different batches of Kromasil-C-18. These experimental band profiles were compared to the profile calculated from the isotherm measured by FA on the first column. The repeatability as well as the column-to-column and the batch-to-batch reproducibilities of the band profiles are better than 4%. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 72
页数:30
相关论文
共 37 条
[1]  
BLUMEL C, 1998, J CHROMATOGR A, V827, P175
[2]   Adsorption of gases in multimolecular layers [J].
Brunauer, S ;
Emmett, PH ;
Teller, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1938, 60 :309-319
[3]   MESSUNG VON ADSORPTIONSISOTHERMEN AN KATALYSATOREN BEI HOHEN TEMPERATUREN MIT HILFE DER GAS-FESTKORPER-ELUIERUNGSCHROMATOGRAPHIE [J].
CREMER, E ;
HUBER, H .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1961, 73 (13) :461-&
[4]   CONTINUOUS FLOW SYSTEMS - DISTRIBUTION OF RESIDENCE TIMES [J].
DANCKWERTS, PV .
CHEMICAL ENGINEERING SCIENCE, 1953, 2 (01) :1-13
[5]   Comparing the optimum performance of the different modes of preparative liquid chromatography [J].
Felinger, A ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 796 (01) :59-74
[6]   Numerical determination of the competitive isotherm of enantiomers [J].
Felinger, A ;
Cavazzini, A ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (02) :207-225
[7]   THEORY OF CHROMATOGRAPHY .10. FORMULAE FOR DIFFUSION INTO SPHERES AND THEIR APPLICATION TO CHROMATOGRAPHY [J].
GLUECKAUF, E .
TRANSACTIONS OF THE FARADAY SOCIETY, 1955, 51 (11) :1540-1551
[9]   Study of the mass transfer kinetics in a monolithic column [J].
Gritti, F ;
Piatkowski, W ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 983 (1-2) :51-71
[10]   Comparison of the adsorption equilibrium of a few low-molecular mass compounds on a monolithic and a packed column in reversed-phase liquid chromatography [J].
Gritti, F ;
Piatkowski, W ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :81-107