Evaluation of automated and semi-automated skull-stripping algorithms using similarity index and segmentation error

被引:57
作者
Lee, JM [1 ]
Yoon, U [1 ]
Nam, SH [1 ]
Kim, JH [1 ]
Kim, IY [1 ]
Kim, SI [1 ]
机构
[1] Hanyang Univ, Coll Med, Dept Biomed Engn, Seoul 133791, South Korea
关键词
skull-stripping; similarity index; false positive rate; false negative rate; simulated T1-weighted MRI; inter-rater reliability; MORPHOMETRIC-ANALYSIS; MRI; CLASSIFICATION; VOLUME;
D O I
10.1016/S0010-4825(03)00022-2
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The skull-stripping in the MR brain image appears to be a key issue in neuroimage analysis. In this paper, we evaluated the accuracy and efficiency of both automated and semi-automated skull-stripping methods. The evaluation was performed on both simulated and real data with the ground truth in skull-stripping. Although automated method showed better efficient results, it should require additional intervention. In contrast to that, semi-automated method showed better accurate results, but it was time consuming and prone to operator bias. Therefore, it might be practical that the semi-automated method was used as the post-processing of the automated one. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:495 / 507
页数:13
相关论文
共 20 条
[1]   Difficulties of T1 brain MRI segmentation techniques [J].
Atkins, MS ;
Siu, K ;
Law, B ;
Orchard, J ;
Rosenbaum, W .
MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 :1837-1844
[2]  
Heinonen T., 1999, International Journal of Bioelectromagnetism, V1, P35
[3]   Automated cerebrum segmentation from three-dimensional sagittal brain MR images [J].
Huh, S ;
Ketter, TA ;
Sohn, KH ;
Lee, CH .
COMPUTERS IN BIOLOGY AND MEDICINE, 2002, 32 (05) :311-328
[4]   ACCURACY AND REPRODUCIBILITY IN VOLUMETRIC-ANALYSIS OF MULTIPLE-SCLEROSIS LESIONS [J].
JACKSON, EF ;
NARAYANA, PA ;
WOLINSKY, JS ;
DOYLE, TJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (02) :200-205
[5]   ANATOMIC SEGMENTATION AND VOLUMETRIC CALCULATIONS IN NUCLEAR MAGNETIC-RESONANCE IMAGING [J].
KENNEDY, DN ;
FILIPEK, PA ;
CAVINESS, VS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (01) :1-7
[6]   Gyri of the human neocortex: An MRI-based analysis of volume and variance [J].
Kennedy, DN ;
Lange, N ;
Makris, N ;
Bates, J ;
Meyer, J ;
Caviness, VS .
CEREBRAL CORTEX, 1998, 8 (04) :372-384
[7]   Grey matter abnormalities in obsessive-compulsive disorder - Statistical parametric mapping of segmented magnetic resonance images [J].
Kim, JJ ;
Lee, MC ;
Kim, J ;
Kim, IY ;
Kim, SI ;
Han, MH ;
Chang, KH ;
Kwon, JS .
BRITISH JOURNAL OF PSYCHIATRY, 2001, 179 :330-334
[8]  
KIM JJ, 2001, P 8 INT C SCHIZ RES, V159
[9]   MRI simulation-based evaluation of image-processing and classification methods [J].
Kwan, RKS ;
Evans, AC ;
Pike, GB .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (11) :1085-1097
[10]   Morphometric analysis of the temporal lobe in temporal lobe epilepsy [J].
Lee, JW ;
Andermann, F ;
Dubeau, F ;
Bernasconi, A ;
MacDonald, D ;
Evans, A ;
Reutens, DC .
EPILEPSIA, 1998, 39 (07) :727-736