Detection of coronary calcification with electron-beam computed tomography: Evaluation of interexamination reproducibility and comparison of three image-acquisition protocols

被引:123
作者
Wang, SJ [1 ]
Detrano, RC [1 ]
Secci, A [1 ]
Tang, WY [1 ]
Doherty, TM [1 ]
Puentes, G [1 ]
Wong, N [1 ]
Brundage, BH [1 ]
机构
[1] ST JOHNS CARDIOVASC RES CTR,TORRANCE,CA 90502
关键词
D O I
10.1016/S0002-8703(96)90237-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this investigation was to determine the variability of electron-beam computed tomography (EBCT) measurement of coronary calcification by using two commonly employed image-acquisition protocols and to compare this variability with that of a new image-acquisition protocol. We performed three EBCT scans within 15 minutes on each of 324 consecutive high-risk, asymptomatic subjects participating in an ongoing epidemiologic research investigation. Subjects were divided into three groups: group 1 (n = 175) received two scans with a standard 20-slice, 3 mm slice thickness image-acquisition protocol and a third scan with the new 20-slice, 6 mm slice thickness protocol; group 2 (n = 77) received two scans with a new 6 mm slice thickness image-acquisition protocol and a third scan with a standard 20-slice, 3 mm slice thickness protocol; group 3 (n = 72) received two scans with a 30-slice, 3 mm slice thickness image-acquisition protocol and a third scan with a 20-slice, 6 mm slice thickness protocol. Calcium score, calcium mass estimate, and calcium volume estimate were determined for each scan. We compared retest variability of calcium measurements for each of the three image-acquisition protocols. The variability of the new 6 mm slice thickness protocol was significantly lower than that of either the 20-slice 3 mm slice thickness protocol (p = 0.009) or the 30-slice 3 mm slice thickness protocol (p = 0.02) for measurement of calcium score, mass, or volume. Retest reproducibility for all three image-acquisition protocols was low; however, the 20-slice 6 mm slice thickness protocol gave reproducibility superior to either of the 3 mm slice thickness protocols. Variability of absolute indices increased, and variability of relative indices decreased as the value of these indices increased. EBCT is not sufficiently reproducible to allow serial quantitation of coronary calcium in individual patients over relatively short periods (<2 years).
引用
收藏
页码:550 / 558
页数:9
相关论文
共 25 条
  • [1] Agatston A.S, 1992, ULTRAFAST COMPUTED T, P77
  • [2] QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY
    AGATSTON, AS
    JANOWITZ, WR
    HILDNER, FJ
    ZUSMER, NR
    VIAMONTE, M
    DETRANO, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 827 - 832
  • [3] SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE
    BIELAK, LF
    KAUFMANN, RB
    MOLL, PP
    MCCOLLOUGH, CH
    SCHWARTZ, RS
    SHEEDY, PF
    [J]. RADIOLOGY, 1994, 192 (03) : 631 - 636
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Blankenhorn DH, 1961, AM J MED SCI, V42, P1
  • [6] CHALLANDE P, 1994, RADIOLOGY, V193, P282, DOI 10.1148/radiology.193.1.282-a
  • [7] Detrano R, 1995, Am J Card Imaging, V9, P167
  • [8] ACCURACY OF QUANTIFYING CORONARY HYDROXYAPATITE WITH ELECTRON-BEAM TOMOGRAPHY
    DETRANO, R
    KANG, XP
    MAHAISAVARIYA, P
    TANG, WY
    COLOMBO, A
    MOLLOI, S
    GARNER, D
    NICKERSON, S
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 (08) : 733 - 738
  • [9] DETRANO RC, 1994, BRIT HEART J, V72, P313
  • [10] PREVALENCE OF FLUOROSCOPIC CORONARY CALCIFIC DEPOSITS IN HIGH-RISK ASYMPTOMATIC PERSONS
    DETRANO, RC
    WONG, ND
    FRENCH, WJ
    TANG, WY
    GEORGIOU, D
    YOUNG, E
    BREZDEN, OS
    DOHERTY, T
    BRUNDAGE, BH
    [J]. AMERICAN HEART JOURNAL, 1994, 127 (06) : 1526 - 1532