Factor G for pipelines with equally spaced multiple outlets and outflow

被引:26
作者
Anwar, AA [1 ]
机构
[1] Univ Southampton, Dept Civil & Environm Engn, Inst Irrigat & Dev Studies, Southampton SO17 1BJ, Hants, England
关键词
D O I
10.1061/(ASCE)0733-9437(1999)125:1(34)
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A factor G for pipelines with equally spaced multiple outlets and outflow at the downstream end is derived. The proposed factor is a function of the number of outlets along the pipeline and also a function of the friction formula used. Factor G allows head loss in such pipelines to be computed directly provided the first outlet is one outlet spacing distance from the pipeline inlet. Under conditions of zero outflow at the downstream end of the pipeline, factor G reduces to the well-known Christiansen's factor F. Factor G allows the design of segments of pipelines with multiple outlets. It may find application with irrigation engineers in designing sprinkler and trickle irrigation laterals and manifolds with multiple-diameter sizes. It also may be used in trickle line hydraulics in flushing mode.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 10 条
[1]  
[Anonymous], 1942, EXP B
[2]  
CHU ST, 1978, T ASAE, V21, P116, DOI 10.13031/2013.35261
[3]  
DETAR WR, 1982, T ASAE, V25, P695, DOI 10.13031/2013.33596
[4]  
James LG, 1988, PRINCIPLES FARM IRRI
[5]  
Jensen MC, 1957, AGR ENG, V38, P247
[6]  
Keller Jack., 1990, SPRINKLE TRICKLE IRR
[7]  
PAIR CH, 1975, IRRIGATION
[8]  
SCALOPPI EJ, 1988, J IRRIG DRAIN ENG, V114, P169, DOI 10.1061/(ASCE)0733-9437(1988)114:1(169)
[9]  
Spiegel M.R., 1968, Mathematical Handbook of Formulas and Tables
[10]  
Schaum's outline series, VVolume 3