Duplex-assisted internal carotid artery balloon angioplasty and stent placement: A novel approach to minimize or eliminate the use of contrast material

被引:20
作者
Ascher, E [1 ]
Marks, NA [1 ]
Schutzer, RW [1 ]
Hingorani, AP [1 ]
机构
[1] Maimonides Hosp, Div Vasc Surg, Brooklyn, NY 11219 USA
关键词
D O I
10.1016/j.jvs.2004.12.040
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Carotid artery balloon angioplasty and stenting (CBAS) is emerging as an acceptable alternative to carotid endarterectomy in selected high-risk patients. Conversely, patients with pre-existing renal impairment, diabetes, or both may be harmed by the nephrotoxic contrast agents required during CBAS. We attempted to limit or eliminate the use of contrast material during CBAS. Methods. Eighteen patients with severe carotid stenoses (> 70%) underwent CBAS at our institution over the last 12 months with duplex scan-assisted CBAS. Of these, 12 were primary procedures, and 6 were performed for carotid re-stenosis. Fourteen patients (78%) were neurologically asymptomatic. The average age of these patients was 75 11 years (range, 44-92 years). Hypertension, chronic renal insufficiency (serum creatinine level >= 1.5 mg/dL), coronary artery disease, diabetes, and smoking were present in 89%, 67%, 59%, 33%, and 28% of patients, respectively. Preoperative duplex carotid mapping was performed in all cases. All procedures were performed with patients under local anesthesia and light sedation. Results. An ATL HDI 5000 scanner with the SonoCT feature was used. The common femoral artery was cannulated with a single-entry needle under direct ultrasound visualization. Fluoroscopy was used to assist passage of the guidewire into the aorta and the common carotid artery. In only four cases (22%) was an aortic arch angiogram obtained. Selective catheterization of the internal and external carotid arteries was performed under ultrasound guidance. The distal cerebral protection device (17 cases) was placed under fluoroscopic guidance. Balloon width and length were chosen according to ultrasound measurements. Balloon and stent deployment were successfully achieved with ultrasound guidance alone in all cases. Appropriate stent apposition and resolution of the stenosis was confirmed by duplex scanning in all cases. Five patients (28%) were noted to have low (< 100 mL/min) internal carotid artery volume flow after stent deployment (range, 20-88 mL/min; mean +/- SD, 50 25 mL/min). The internal carotid artery volume flow increased immediately after Filterwire retrieval in all cases and ranged from 136 to 400 mL/min (mean, 245 107 mL/min). This increase was statistically significant (P < .02). No ipsilateral strokes or deaths occurred during follow-up from 1 to 12 months (mean follow-up, 5 months). Conclusions: Duplex scan-assisted CBAS is feasible and may reduce the need for intra-arterial contrast injection in selected patients deemed at high risk for renal failure from nephrotoxic contrast material. Additional advantages include direct visualization of the puncture site, precise position of the balloon and stent, and B-mode and hemodynamic confirmation of the adequacy of the technique.
引用
收藏
页码:409 / 415
页数:7
相关论文
共 12 条
[1]  
Ahmadi R, 2002, J ENDOVASC THER, V9, P873, DOI 10.1583/1545-1550(2002)009<0873:DUGFAI>2.0.CO
[2]  
2
[3]   Internal carotid artery flow volume measurement and other intraoperative duplex scanning parameters as predictors of stroke after carotid endarterectomy [J].
Ascher, E ;
Markevich, N ;
Hingorani, AP ;
Kallakuri, S ;
Gunduz, Y .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (03) :439-444
[4]   Changing characteristics of carotid endarterectomy [J].
Ascher, E ;
Hingorani, A .
ANNALS OF VASCULAR SURGERY, 2001, 15 (03) :275-280
[5]   Duplex ultrasound insertion of inferior vena cava filters in multitrauma patients [J].
Benjamin, ME ;
Sandager, GP ;
Cohn, EJ ;
Halloran, BG ;
Cahan, MA ;
Lilly, MP ;
Scalea, TM ;
Flinn, WR .
AMERICAN JOURNAL OF SURGERY, 1999, 178 (02) :92-97
[6]   Deep venous thrombosis after radiofrequency ablation of greater saphenous vein: A word of caution [J].
Hingorani, AP ;
Ascher, E ;
Markevich, N ;
Schutzer, RW ;
Kallakuri, S ;
Hou, A ;
Nahata, S ;
Yorkovich, W ;
Jacob, T .
JOURNAL OF VASCULAR SURGERY, 2004, 40 (03) :500-504
[7]   RADIOCONTRAST-ASSOCIATED RENAL DYSFUNCTION - INCIDENCE AND RISK-FACTORS [J].
LAUTIN, EM ;
FREEMAN, NJ ;
SCHOENFELD, AH ;
BAKAL, CW ;
HARAMATI, N ;
FRIEDMAN, AC ;
LAUTIN, JL ;
BRAHA, S ;
KADISH, EG ;
SPRAYREGEN, S ;
BELIZON, I .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :49-58
[8]   RADIOCONTRAST-ASSOCIATED RENAL DYSFUNCTION - A COMPARISON OF LOWER-OSMOLALITY AND CONVENTIONAL HIGH-OSMOLALITY CONTRAST-MEDIA [J].
LAUTIN, EM ;
FREEMAN, NJ ;
SCHOENFELD, AH ;
BAKAL, CW ;
HARAMITI, N ;
FRIEDMAN, AC ;
LAUTIN, JL ;
BRAHA, S ;
KADISH, EG ;
SPRAYREGEN, S ;
BELIZON, I .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :59-65
[9]   Prospective randomized study of endovenous radiofrequency obliteration (Closure procedure) versus ligation and stripping in a selected patient population (EVOLVeS Study) [J].
Lurie, F ;
Creton, D ;
Eklof, B ;
Kabnick, LS ;
Kistner, RL ;
Pichot, O ;
Schuller-Petrovic, S ;
Sessa, C .
JOURNAL OF VASCULAR SURGERY, 2003, 38 (02) :207-214
[10]  