VD-AUTO-SMASH imaging

被引:189
作者
Heidemann, RM [1 ]
Griswold, MA [1 ]
Haase, A [1 ]
Jakob, PM [1 ]
机构
[1] Univ Wurzburg, Dept Phys, D-97074 Wurzburg, Germany
关键词
SMASH; AUTO-SMASH; simultaneous acquisition; PPA; RF coil array; MR image reconstruction;
D O I
10.1002/mrm.1141
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently a self-calibrating SMASH technique, AUTO-SMASH, was described. This technique is based on PPA with RF coil arrays using auto-calibration signals. In AUTO-SMASH, important coil sensitivity information required for successful SMASH reconstruction is obtained during the actual scan using the correlation between undersampled SMASH signal data and additionally sampled calibration signals with appropriate offsets in k-space. However, AUTO-SMASH is susceptible to noise in the acquired data and to imperfect spatial harmonic generation in the underlying coil array. In this work, a new modified type of internal sensitivity calibration, VD-AUTO-SMASH, is proposed. This method uses a VD k-space sampling approach and shows the ability to improve the image quality without significantly increasing the total scan time. This new k-space adapted calibration approach is based on a k-space-dependent density function. In this scheme, fully sampled low-spatial frequency data are acquired up to a given cutoff-spatial frequency. Above this frequency, only sparse SMASH-type sampling is performed. On top of the VD approach, advanced fitting routines, which allow an improved extraction of coil-weighting factors in the presence of noise, are proposed. It is shown in simulations and in vivo cardiac images that the VD approach significantly increases the potential and flexibility of rapid imaging with AUTO-SMASH. (C) 2001 WiIey-Liss, inc.
引用
收藏
页码:1066 / 1074
页数:9
相关论文
共 20 条
  • [1] Bankson JA, 2000, MAGN RESON MATER PHY, V10, P93
  • [2] IMAGING TIME REDUCTION THROUGH MULTIPLE RECEIVER COIL DATA ACQUISITION AND IMAGE-RECONSTRUCTION
    CARLSON, JW
    MINEMURA, T
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) : 681 - 688
  • [3] Griswold MA, 2000, MAGN RESON MED, V44, P602, DOI 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO
  • [4] 2-5
  • [5] Griswold MA, 1999, MAGNET RESON MED, V41, P1236, DOI 10.1002/(SICI)1522-2594(199906)41:6<1236::AID-MRM21>3.0.CO
  • [6] 2-T
  • [7] Griswold MA, 2000, MAGN RESON MATER PHY, V10, P105
  • [8] Jakob PM, 1998, MAGN RESON MATER PHY, V7, P42
  • [9] Kyriakos WE, 2000, MAGNET RESON MED, V44, P301, DOI 10.1002/1522-2594(200008)44:2<301::AID-MRM18>3.0.CO
  • [10] 2-D