Construction and dynamic test of a small-scale organic rankine cycle

被引:208
作者
Pei, Gang [1 ]
Li, Jing [1 ]
Li, Yunzhu [1 ]
Wang, Dongyue [1 ]
Ji, Jie [1 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China
基金
美国国家科学基金会;
关键词
Turbine; Organic rankine cycle; Cavitation; Converter frequency; THERMAL ELECTRIC GENERATION; SOLAR COLLECTOR/CHP SYSTEM; HEAT; PERFORMANCE; DESIGN; FLUIDS;
D O I
10.1016/j.energy.2011.03.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
The fundamentals of a newly constructed kW-scale Organic Rankine Cycle (ORC) system on the use of R123 were illustrated. A specially designed and manufactured turbine was innovatively applied to this system. Formulations were developed to examine the heat transfer and power conversion processes of the ORC. Unlike water pumping, the vapor pressure of the pumped fluid in the ORC system was much higher, and cavitation was more easily facilitated. A technology was introduced to address this issue without a large height difference between the tank and the pump. A preliminary test of the constructed system under varying conditions was conducted. The mass flow rate through the pump was found to be unequal to that through the turbine during the converter frequency adjustment process. The two mass flow rates were influenced in different ways by the evaporator pressure. The experiment results show that a turbine isentropic efficiency of 0.65 and an ORC efficiency of 6.8% can be obtained with a temperature difference of about 70 degrees C between the hot and the cold sides. Overall, the turbine has demonstrated adequate performance by operating at off-design conditions, which underscores its potential for application in small-scale ORCs. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3215 / 3223
页数:9
相关论文
共 29 条
[1]   Rapid screening of fluids for chemical stability in organic rankine cycle applications [J].
Andersen, WC ;
Bruno, TJ .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (15) :5560-5566
[2]  
BADR O, 1986, P I MECH ENG A-J POW, V200, P117
[3]   CORRELATING EQUATIONS FOR LAMINAR AND TURBULENT FREE CONVECTION FROM A HORIZONTAL CYLINDER [J].
CHURCHILL, SW ;
CHU, HHS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1975, 18 (09) :1049-1053
[4]   Process integration of organic Rankine cycle [J].
Desai, Nishith B. ;
Bandyopadhyay, Santanu .
ENERGY, 2009, 34 (10) :1674-1686
[5]  
GANG P, 2010, POW EN ENG C APPEEC, DOI DOI 10.1109/APPEEC
[6]  
2010.5449529
[7]   Analysis of low temperature solar thermal electric generation using regenerative Organic Rankine Cycle [J].
Gang, Pei ;
Jing, Li ;
Jie, Ji .
APPLIED THERMAL ENGINEERING, 2010, 30 (8-9) :998-1004
[8]   Optimum design criteria for an Organic Rankine cycle using low-temperature geothermal heat sources [J].
Hettiarachchia, H. D. Madhawa ;
Golubovica, Mihajlo ;
Worek, William M. ;
Ikegami, Yasuyuki .
ENERGY, 2007, 32 (09) :1698-1706
[9]   Waste heat recovery of organic Rankine cycle using dry fluids [J].
Hung, TC .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (05) :539-553
[10]  
JAMES AM, 2009, J ENERGY RESOURCES T, V131