Recent advances in continuous glucose monitoring

被引:17
作者
Freckmann, G
Kalatz, B
Pfeiffer, B
Hoss, U
Haug, C
机构
[1] Univ Ulm, Inst Diabet Technol, D-89081 Ulm, Germany
[2] Univ Hosp Ulm, Inst Clin Chem, Ulm, Germany
关键词
continuous glucose monitoring; microdialysis; tissue glucose; feedback-controlled insulin infusion; closed-loop system;
D O I
10.1055/s-2001-18594
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Continuous glucose monitoring, providing more detailed information on glucose excursions than single spot measurements, should help to improve the therapy in diabetic patients and is also required for feedback-controlled insulin delivery. At the Institute for Diabetes-Technology in Ulm, founded by EF Pfeiffer, a portable glucose sensor for continuous tissue glucose monitoring has been developed. The combination of microdialysis and enzymatic amperometric glucose measurement implemented in this device marked a break-through in achieving reliable and precise continuous tissue glucose monitoring. In several studies, we have demonstrated that continuous subcutaneous glucose monitoring for up to 72 hours is feasible under 'in-house' and 'daily life' conditions in diabetic patients. The measured tissue glucose concentrations correlated closely to glucose control measurements in venous and capillary blood. A reliable continuous glucose monitoring device is a prerequisite for the development of an artificial pancreas. Our group developed an algorithm for subcutaneous application of the fast acting insulin analogon lispro. In experiments performed over 7 and 24 hours good metabolic control was achieved by algorithm-based insulin application. In addition, the algorithm was able to maintain acceptable metabolic control during and after moderate physical exercise. Further work is needed to optimize continuous tissue glucose monitoring systems and to develop a closed loop system for insulin application based on continuously measured tissue glucose concentrations.
引用
收藏
页码:S347 / S357
页数:11
相关论文
共 26 条
[1]  
*AM DIAB ASS, 2000, DIABETES CARE S1, V23, P32
[2]   Hypoglycemia in the diabetes control and complications trial [J].
不详 .
DIABETES, 1997, 46 (02) :271-286
[3]   ABSORPTION KINETICS AND BIOLOGIC EFFECTS OF SUBCUTANEOUSLY INJECTED INSULIN PREPARATIONS [J].
BERGER, M ;
CUPPERS, HJ ;
HEGNER, H ;
JORGENS, V ;
BERCHTOLD, P .
DIABETES CARE, 1982, 5 (02) :77-91
[4]   INSULIN PHARMACOKINETICS [J].
BINDER, C ;
LAURITZEN, T ;
FABER, O ;
PRAMMING, S .
DIABETES CARE, 1984, 7 (02) :188-199
[5]  
Hoss U, 1999, DIABETES, V48, pA103
[6]  
Hoss U., 1998, Hormone and Metabolic Research, V30, pA14
[7]  
Hoss U., 1996, Hormone and Metabolic Research, V28, P45
[8]  
Hoss U, 1998, DIABETOLOGIA, V41, pA45
[9]  
HOSS U, 1997, THESIS ULM
[10]   [LYS(B28), PRO(B29)]-HUMAN INSULIN - A RAPIDLY ABSORBED ANALOG OF HUMAN INSULIN [J].
HOWEY, DC ;
BOWSHER, RR ;
BRUNELLE, RL ;
WOODWORTH, JR .
DIABETES, 1994, 43 (03) :396-402