Transdermal microconduits by microscission for drug delivery and sample acquisition

被引:27
作者
Herndon, Terry O. [1 ]
Gonzalez, Salvador [2 ]
Gowrishankar, T. R. [1 ]
Anderson, R. Rox [1 ,2 ]
Weaver, James C. [1 ]
机构
[1] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[2] Harvard Univ, Wellman Labs Photomed, Dept Dermatol, Massachusetts Gen Hosp,Med Sch, Boston, MA 02114 USA
关键词
D O I
10.1186/1741-7015-2-12
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Painless, rapid, controlled, minimally invasive molecular transport across human skin for drug delivery and analyte acquisition is of widespread interest. Creation of microconduits through the stratum corneum and epidermis is achieved by stochastic scissioning events localized to typically 250 mu m diameter areas of human skin in vivo. Methods: Microscissioning is achieved by a limited flux of accelerated gas: 25 mu m inert particles passing through the aperture in a mask held against the stratum corneum. The particles scize (cut) tissue, which is removed by the gas flow with the sensation of a gentle stream of air against the skin. The resulting microconduit is fully open and may be between 50 and 200 mu m deep. Results: In vivo adult human tests show that microconduits reduce the electrical impedance between two ECG electrodes from approximately 4,000 Omega to 500 Omega. Drug delivery has been demonstrated in vivo by applying lidocaine to a microconduit from a cotton swab. Sharp point probing demonstrated full anaesthesia around the site within three minutes. Topical application without the microconduit required approximately 1.5 hours. Approximately 180 mu m deep microconduits in vivo yielded blood sample volumes of several mu l, with a faint pricking sensation as blood enters tissue. Blood glucose measurements were taken with two commercial monitoring systems. Microconduits are invisible to the unaided eye, developing a slight erythematous macule that disappears over days. Conclusion: Microscissioned microconduits may provide a minimally invasive basis for delivery of any size molecule, and for extraction of interstitial fluid and blood samples. Such microconduits reduce through-skin electrical impedance, have controllable diameter and depth, are fully open and, after healing, no foreign bodies were visible using through-skin confocal microscopy. In subjects to date, microscissioning is painless and rapid.
引用
收藏
页数:11
相关论文
共 19 条
[1]   Epidemiology of diabetes [J].
Gadsby, R .
ADVANCED DRUG DELIVERY REVIEWS, 2002, 54 (09) :1165-1172
[2]   Microfabricated microneedles: A novel approach to transdermal drug delivery [J].
Henry, S ;
McAllister, DV ;
Allen, MG ;
Prausnitz, MR .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (08) :922-925
[3]  
Hernandez E, 1998, LASER SURG MED, V23, P167, DOI 10.1002/(SICI)1096-9101(1998)23:3<167::AID-LSM6>3.3.CO
[4]  
2-J
[5]   Microfabrication of individual 200 μm diameter transdermal microconduits using high voltage pulsing in salicylic acid and benzoic acid [J].
Ilic, L ;
Gowrishankar, TR ;
Vaughan, TE ;
Herndon, TO ;
Weaver, JC .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2001, 116 (01) :40-49
[6]   CONTROLLED REMOVAL OF HUMAN STRATUM-CORNEUM BY PULSED LASER [J].
JACQUES, SL ;
MCAULIFFE, DJ ;
BLANK, IH ;
PARRISH, JA .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1987, 88 (01) :88-93
[7]   Sonicated transdermal drug transport [J].
Joshi, A ;
Raje, J .
JOURNAL OF CONTROLLED RELEASE, 2002, 83 (01) :13-22
[8]   Structure-activity relationship of chemical penetration enhancers in transdermal drug delivery [J].
Kanikkannan, N ;
Kandimalla, K ;
Lamba, SS ;
Singh, M .
CURRENT MEDICINAL CHEMISTRY, 2000, 7 (06) :593-608
[9]  
Langer R, 1998, NATURE, V392, P5
[10]  
Lee S, 1997, J INVEST DERMATOL, V108, P786