On field calibration of an electronic nose for benzene estimation in an urban pollution monitoring scenario

被引:375
作者
De Vito, S. [1 ]
Massera, E. [1 ]
Piga, A. [2 ]
Martinotto, L. [2 ]
Di Francia, G. [1 ]
机构
[1] ENEA, Ctr Ric Portici, I-80055 Portici, NA, Italy
[2] Pirelli Labs, I-20126 Milan, Italy
关键词
electronic nose; multi-sensor device; urban atmospheric pollution; benzene monitoring; artificial neural networks; on-line calibration;
D O I
10.1016/j.snb.2007.09.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Low-cost gas multi-sensor devices could be efficiently used for densifying the sparse urban pollution monitoring mesh if equipped with a reliable calibration able to counter specificity and stability issues of solid-state sensors they rely on. In this work, we present a neural calibration for the prediction of benzene concentrations using a gas multi-sensor device (solid-state) designed to monitor urban environment pollution. The feasibility of a sensor fusion algorithm as a calibrating tool for the multi-sensor device is discussed. A Conventional air pollution monitoring station is used to provide reference data. Results are assessed by means of prediction error characterization throughout a 13 months long interval and discussed. Relationship between training length and performances are also investigated. A neural calibration obtained using a small number of measurement days revealed to be capable to limit the absolute prediction error for more than 6th month, after which seasonal influences on prediction capabilities at low-concentrations suggested the need for a further calibration. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:750 / 757
页数:8
相关论文
共 23 条
[1]  
Bishop CM., 1995, Neural networks for pattern recognition
[2]  
Brezmes J, 2005, STUD FUZZ SOFT COMP, V177, P365
[3]   Nanostructured thick-film gas sensors for atmospheric pollutant monitoring:: quantitative analysis on field tests [J].
Carotta, MC ;
Martinelli, C ;
Crema, L ;
Malagú, C ;
Merli, M ;
Ghiotti, G ;
Traversa, E .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) :336-342
[4]   Array of thick film sensors for atmospheric pollutant monitoring [J].
Carotta, MC ;
Martinelli, G ;
Crema, L ;
Gallana, M ;
Merli, M ;
Ghiotti, G ;
Traversa, E .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) :1-8
[5]  
CROXFORD B, 1995, P 5 S HIGHW URB POLL
[6]   Gas concentration estimation in ternary mixtures with room temperature operating sensor array using tapped delay architectures [J].
De Vito, Saverio ;
Castaldo, Anna ;
Loffredo, Fausta ;
Massera, Ettore ;
Polichetti, Tiziana ;
Nasti, Lvana ;
Vacca, Paolo ;
Quercia, Luigi ;
Di Francia, Girolamo .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (02) :309-316
[7]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[8]   TRAINING FEEDFORWARD NETWORKS WITH THE MARQUARDT ALGORITHM [J].
HAGAN, MT ;
MENHAJ, MB .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 1994, 5 (06) :989-993
[9]   Simultaneous quantification of carbon monoxide and methane in humid air using a sensor array and an artificial neural network [J].
Huyberechts, G ;
Szecowka, P ;
Roggen, J ;
Licznerski, BW .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (02) :123-130
[10]   Calibration of a multivariate gas sensing device for atmospheric pollution measurement [J].
Kamionka, M. ;
Breuil, P. ;
Pijolat, C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 118 (1-2) :323-327