Use of the quartz crystal microbalance to measure the mass of submonolayer deposits: Measuring the stoichiometry of surface oxides

被引:29
作者
Narine, SS [1 ]
Slavin, AJ [1 ]
机构
[1] Trent Univ, Peterborough, ON K9J 7B8, Canada
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS | 1998年 / 16卷 / 03期
关键词
D O I
10.1116/1.581118
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This article describes a high-resolution quartz crystal microbalance (QCM) with a reproducibility of 0.2 Hz at 6 MHz, provided the frequency is always measured at the same temperature of the microbalance to within 0.1 degrees C. This enables the microbalance to measure a change in mass equivalent to about 0.1 monolayer of oxygen atoms. Due to its high mass sensitivity, the QCM can be used for absolute measurements of the stoichiometry of ultrathin oxide films. An absolute measure of the stoichiometry of ultrathin metal oxides is difficult to obtain by other means. In this technique, one measures the frequency shift after the deposition of about one monolayer of the metal film onto the gold electrode of the quartz crystal, in ultrahigh vacuum. The deposited film is then oxidized to completion in a low pressure of oxygen gas, and the frequency shift measured again, at the same temperature as before. The ratio of the frequency shifts and the atomic masses gives the oxide stoichiometry. Following the complete oxidation of submonolayer amounts of Sb on the polycrystalline gold electrode of the QCM, the ratio of oxygen to antimony atoms was measured to be unity. However, it is suggested that the stoichiometry of the oxide formed may be SbAuO rather than SbO, since the latter does not satisfy valency considerations. The accuracy of the microbalance measurements has been checked using an inductively coupled-plasma mass spectrometer, which can easily measure,; ex situ, the mass of a monolayer deposit with an accuracy of a few percent. (C) 1998 American Vacuum Society.
引用
收藏
页码:1857 / 1862
页数:6
相关论文
共 24 条
[1]  
[Anonymous], [No title captured]
[2]  
BOERSMA F, 1975, PROGR VACUUM MICRO 1, V3, P9
[3]  
CARLSON TA, 1975, PHOTOELECTRON AUGER, V134, P499
[4]   The time-resolved EQCM and study of the kinetics of silver(I) oxide formation on a polycrystalline silver electrode in alkaline solution [J].
Chen, SL ;
Wu, BL ;
Cha, CS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 420 (1-2) :111-118
[5]   STM STUDY OF THE SURFACE-MORPHOLOGY OF GOLD ON MICA [J].
CHIDSEY, CED ;
LOIACONO, DN ;
SLEATOR, T ;
NAKAHARA, S .
SURFACE SCIENCE, 1988, 200 (01) :45-66
[6]   THE QUARTZ CRYSTAL MICROBALANCE - RADIAL POLAR DEPENDENCE OF MASS SENSITIVITY BOTH ON AND OFF THE ELECTRODES [J].
CUMPSON, PJ ;
SEAH, MP .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1990, 1 (07) :544-555
[7]   GOLD GROWN EPITAXIALLY ON MICA - CONDITIONS FOR LARGE AREA FLAT FACES [J].
DEROSE, JA ;
THUNDAT, T ;
NAGAHARA, LA ;
LINDSAY, SM .
SURFACE SCIENCE, 1991, 256 (1-2) :102-108
[8]  
EERNISSE EP, 1984, APPLICATIONS PIEZOEL, P125
[9]  
ELBEL N, 1995, J VAC SCI TECHNOL B, V13, P119
[10]  
Feldman L. C., 1986, Fundamentals of Surface and Thin Film Analysis