Time-of-Flight PET

被引:105
作者
Lewellen, TK [1 ]
机构
[1] Univ Washington, Med Ctr, Div Nucl Med, Seattle, WA 98195 USA
关键词
D O I
10.1016/S0001-2998(98)80031-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Time-of-Flight (TOF) positron emission tomographs (PET) were developed during the 1980s and early 1990s. Initial investigations into the potential improvements in signal-to-noise ratios if TOF information was utilized were published in 1980. By 1982. two groups (Washington University and Commissariat a I'Energie Atomique-Laboratorie d'Electronique et de L'Informatique [CEA-LETI]) were designing and building the first TOF tomographs. A third group at the University of Texas also designed and built a TOF system. These systems were optimized for high count-rate imaging of short-lived radiotracers for applications such as cardiac blood flow, The first system put into operation for patient scans was the Super PETT I built at Washington University by Michel Ter-Pogossian and his colleagues. The Washington University group went on to design two additional versions of TOF systems and the CEA-LETI group developed two basic tomograph designs, As Bismuth Germanate (BGO)based scanners were refined, it became clear that the TOF systems could not provide the same high spatial resolution as offered by the newer systems. The use of the fast scintillators required for TOF systems also resulted in lower intrinsic sensitivity that was only partially compensated for by the effective gain in sensitivity offered by TOF image reconstruction techniques. Further development of TOF systems was suspended in the early 1990s. With the development of new scintillators that provide more light output and are denser than those available in the 1980s and considerably faster than EGO. there is new interest in the application of TOF techniques for future tomograph designs. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:268 / 275
页数:8
相关论文
共 49 条
[1]  
ALLEMAND R, 1980, J NUCL MED, V21, P153
[2]   A TECHNIQUE FOR THE CORRECTION OF SCATTERED RADIATION IN A PET SYSTEM USING TIME-OF-FLIGHT INFORMATION [J].
BENDRIEM, B ;
SOUSSALINE, F ;
CAMPAGNOLO, R ;
VERREY, B ;
WAJNBERG, P ;
SYROTA, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (02) :287-295
[3]  
BICE A N, 1990, Journal of Nuclear Medicine, V31, P863
[4]   MONTE-CARLO SIMULATION OF BAF2 DETECTORS USED IN TIME-OF-FLIGHT POSITRON EMISSION TOMOGRAPHY [J].
BICE, AN ;
LEWELLEN, TK ;
MIYAOKA, RS ;
HARRISON, RL ;
HAYNOR, DR ;
POLLARD, KR ;
ANSON, CP ;
GILLISPIE, SB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :696-701
[5]  
CAMPAGNOLO R, 1979, C NATL TRAITEMENT SI, P100
[6]   A SIMPLIFIED EM RECONSTRUCTION ALGORITHM FOR TOFPET [J].
CHEN, CT ;
METZ, CE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) :885-888
[7]  
CHESLER DA, 1982, P WORKSH TIM FLIGHT, P113
[8]  
FARUKHI MR, 1982, P WORKSH TIM FLIGHT, P59
[9]   RECENT DEVELOPMENTS IN IMAGE-RECONSTRUCTION USING A TIME-OF-FLIGHT-ASSISTED POSITRON EMISSION TOMOGRAPH - SUPER PETT-I [J].
FICKE, DC ;
BEECHER, DE ;
HOFFMAN, GR ;
HOLMES, TJ ;
TERPOGOSSIAN, MM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :605-608
[10]  
FICKE DC, 1982, P WORKSH TIM FLIGHT, P139