A randomised trial of endoluminal reconstruction comparing the NIR stent and the wallstent in angioplasty of long segment coronary disease: Results of the RENEWAL Study

被引:14
作者
Nageh, T
de Belder, AJ
Thomas, MR
Williams, IL
Wainwright, RJ
机构
[1] Kings Coll London Hosp, Dept Cardiol, London SE5 9RS, England
[2] Royal Sussex Cty Hosp, Dept Cardiol, Brighton BN2 5BE, E Sussex, England
关键词
D O I
10.1067/mhj.2001.115301
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The role of coronary stents in reducing the incidence of acute complications and late restenosis after angioplasty has been established in randomized studies focusing on simple, short coronary lesions. The development of long coronary stents has provided a safe and predictable means of treating long coronary lesions, but this carries with it a higher risk of restenosis. By comparing the outcome of treating long lesions with two different stent types, we aimed to assess the influence of stent design rather than the nature of long lesions per se on the relatively high restenosis rates in this subgroup. Methods This study was designed to assess procedural complications and 6-month restenosis rates in a randomized trial comparing a slotted tube stent with a self-expanding stent for the treatment of long coronary lesions. Randomization of vessels to either stent occurred after successful balloon angioplasty. Intravascular ultrasound (IVUS) was used to assess and optimize stent deployment. The patients were restudied angiographically and by IVUS at 6 months. Results A total of 82 patients (85 vessels) were recruited (slotted tube stent n = 44 vessels, self-expanding stent, n = 41 vessels). Successful deployment occurred in 41 (100%) of 41 of the self-expanding stent group and 41 (93%) of 44 of the slotted tube stent group. There was no difference in lesion length between the two groups (slotted tube stent, 26.6 +/- 6.9 [SD] mm; self-expanding stent, 28.7 +/- 9.8 [SD] mm; P = .2), but the mean length of the self-expending stent was greater than that of the slotted tube stent (41.6 +/- 18.8 [SD] mm vs 35.4 +/- 16.2 [SD] mm, respectively; P < .05). There was no significant difference in the rate of major events between the two groups at 6-month follow-up. The angiographic restenosis rate at follow-up was less in the slotted tube stent group, but this did not reach statistical significance (26% vs 46%, respectively; P = .1) and the target lesion revascularization rate was similar for both groups (7.9% vs 7.7%, respectively; P = .8). IVUS assessment of plaque/stent ratios suggested a greater plaque burden in the self-expanding stent compared with the slotted tube stent at follow-up (0.42 +/- 1.2 [SD] vs 0.3 +/- 0.08 [SD]), but this was not statistically significant (P = .1). Conclusions Long stents can be safely and successfully deployed in long segment coronary disease, with an accept able 6-month target lesion revascularization rate. Our results showed a trend toward lower angiographic restenosis and a lesser in-stent plaque burden at follow-up in the slotted tube stent compared with the self expanding stent. This suggests that stent design may influence the restenotic process in long coronary lesions.
引用
收藏
页码:971 / 976
页数:6
相关论文
共 20 条
[1]   CLINICAL, PHYSIOLOGICAL, ANATOMIC AND PROCEDURAL FACTORS PREDICTIVE OF RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
BOURASSA, MG ;
LESPERANCE, J ;
EASTWOOD, C ;
SCHWARTZ, L ;
COTE, G ;
KAZIM, F ;
HUDON, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (02) :368-376
[2]   Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[3]   LOCAL LESION-RELATED FACTORS AND RESTENOSIS AFTER CORONARY ANGIOPLASTY - EVIDENCE FROM A QUANTITATIVE ANGIOGRAPHIC STUDY IN PATIENTS WITH UNSTABLE ANGINA UNDERGOING DOUBLE-VESSEL ANGIOPLASTY [J].
DEGROOTE, P ;
BAUTERS, C ;
MCFADDEN, EP ;
LABLANCHE, JM ;
LEROY, F ;
BERTRAND, ME .
CIRCULATION, 1995, 91 (04) :968-972
[4]   CORONARY MORPHOLOGICAL AND CLINICAL DETERMINANTS OF PROCEDURAL OUTCOME WITH ANGIOPLASTY FOR MULTIVESSEL CORONARY-DISEASE - IMPLICATIONS FOR PATIENT SELECTION [J].
ELLIS, SG ;
VANDORMAEL, MG ;
COWLEY, MJ ;
DISCIASCIO, G ;
DELIGONUL, U ;
TOPOL, EJ ;
BULLE, TM .
CIRCULATION, 1990, 82 (04) :1193-1202
[5]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[6]  
HIRSHFIELD JW, 1991, J AM COLL CARDIOL, V18, P368
[7]   Predictive factors of restenosis after coronary stent placement [J].
Kastrati, A ;
Schomig, A ;
Elezi, S ;
Schuhlen, H ;
Dirschinger, J ;
Hadamitzky, M ;
Wehinger, A ;
Hausleiter, J ;
Walter, H ;
Neumann, FJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (06) :1428-1436
[8]  
KOBOYASHI Y, 1996, CIRCULATION S1, V96, P472
[9]   Multivessel Palmaz-Schatz stenting: Early results and one-year outcome [J].
Laham, RJ ;
Ho, KKL ;
Baim, DS ;
Kuntz, RE ;
Cohen, DJ ;
Carrozza, JP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (01) :180-185
[10]   Clinical and angiographic results of stenting for long coronary arterial atherosclerotic lesions [J].
Le Breton, H ;
Bedossa, M ;
Commeau, P ;
Boschat, J ;
Huret, B ;
Gilard, M ;
Brunel, P ;
Crochet, D ;
Grollier, G ;
Douillet, R ;
Koning, R ;
Lefebvre, E ;
Meselhy, M ;
Leclercq, C ;
Pony, JC .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (12) :1539-+