Angulated screw placement in the lateral condylar buttress plate for supracondylar femoral fractures

被引:29
作者
Simonian, PT [1 ]
Thompson, GJ [1 ]
Emley, W [1 ]
Harrington, RM [1 ]
Benirschke, SK [1 ]
Swiontkowski, MF [1 ]
机构
[1] Univ Washington, Harborview Med Ctr, Dept Orthopaed, Biomech Lab, Seattle, WA 98104 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 1998年 / 29卷 / 02期
关键词
D O I
10.1016/S0020-1383(97)00140-X
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Certain supracondylar femoral fractures are not amenable to internal fixation with fixed angle devices. In these instances, the condylar buttress plate is the recommended alternative; however, this is a less rigid device. Because of the decreased rigidity and strength of this device, there is a tendency toward varus angulation and malunion. In six fresh-frozen human knee specimens, segmental osteotomies were created to mimic supracondylar femoral fractures. The medial cortex was completely removed to make the fracture unstable to varus deformity. The fracture was fixed with a lateral condylar buttress plate using 4.5 mm screws. Each specimen was tested once with all the screws installed perpendicular to the plate, and again with the middle screw just proximal to the fracture, angled 45 degrees diagonally across the fracture into the subchondral bone of the medial femoral condyte. For the construct with all screws placed perpendicular to the buttress plate, the initial stiffness was 410 N/mm, and after 1000 cycles it was 230 N/mm. With a screw placed diagonally across the fracture site, stiffness increased to 833 N/mm on the first cycle, and 796 N/mm after 1000 cycles. In all specimens with the screws placed perpendicular to the plate, the distal fragment had a permanent varus deformity after 1000 cycles, under no load, of 0.91 mm. For the diagonal screw condition, the average magnitude far all six specimens was 0.42 mm. This simple means of screw angulation in the plate strengthened the overall construct to resist the tendency toward varus deformity. The attractive features include the ease of application, and the use of an existing construct. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:101 / 104
页数:4
相关论文
共 8 条
[1]
MECHANICS OF RETROGRADE NAIL VERSUS PLATE FIXATION FOR SUPRACONDYLAR FEMUR FRACTURES [J].
FIROOZBAKHSH, K ;
BEHZADI, K ;
DECOSTER, TA ;
MONEIM, MS ;
NARAGHI, FF .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (02) :152-157
[2]
BLADE-PLATING OF CLOSED DISPLACED SUPRACONDYLAR FRACTURES OF THE DISTAL FEMUR WITH THE AO SYSTEM [J].
MERCHAN, ECR ;
MAESTU, PR ;
BLANCO, RP .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1992, 32 (02) :174-178
[3]
SUPRACONDYLAR FRACTURES OF THE FEMUR [J].
NEWMAN, JH .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1990, 21 (05) :280-282
[4]
DOUBLE-PLATING OF COMMINUTED, UNSTABLE FRACTURES OF THE DISTAL PART OF THE FEMUR [J].
SANDERS, R ;
SWIONTKOWSKI, M ;
ROSEN, H ;
HELFET, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (03) :341-346
[5]
SUPRACONDYLAR FRACTURE OF THE FEMUR - CLOSED OR OPEN REDUCTION [J].
SHAHCHERAGHI, GH ;
DOROODCHI, HR .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 34 (04) :499-502
[6]
Struhl S, 1990, J Orthop Trauma, V4, P151, DOI 10.1097/00005131-199004020-00008
[7]
SUPRACONDYLAR FRACTURES OF THE FEMUR [J].
YANG, RS ;
LIU, HC ;
LIU, TK .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1990, 30 (03) :315-319
[8]
Zehntner M K, 1992, J Orthop Trauma, V6, P318, DOI 10.1097/00005131-199209000-00009