Determination of ammonia in wastewaters containing high concentrations of surfactants by flow injection potentiometry with on-line sample clean-up

被引:12
作者
Shen, HD [1 ]
Cardwell, TJ [1 ]
Cattrall, RW [1 ]
机构
[1] La Trobe Univ, Sch Chem, Ctr Sci Instrumentat, Bundoora, Vic 3083, Australia
基金
澳大利亚研究理事会;
关键词
ammonia; surfactants; wastewaters; flow injection; activated carbon; potentiometry; nonactin electrode;
D O I
10.1016/S0003-2670(98)00168-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is demonstrated that surfactants lead to problems in the analysis of ammonia in gas-diffusion flow injection by wetting the membrane to allow transport of potentially interfering species to the detector. An on-line clean-up procedure, involving use of an activated carbon cartridge, is described for the removal of ionic and non-ionic surfactants (up to 1000 mg l(-1)) and other organic compounds from aqueous samples. Ammoniacal nitrogen was determined in synthetic samples by gas-diffusion flow injection with a nonactin-based potentiometric sensor used as the detector for the ammonium ion. Analyses could be performed at a sampling rate of ca. 25 h(-1) and the cartridge was effective for at least 1000 injections of 50 mu l samples in the concentration range 1-180 mg l(-1). The procedure was applied to the analysis of wastewaters and was found to be efficient in removing ionic and non-ionic surfactants from acidified (pH 1) samples. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 13 条
[1]   DETERMINATION OF AMMONIA IN WINE AND MILK WITH AN AMMONIA GAS-SENSING PROBE [J].
BERNAL, JL ;
DELNOZAL, MJ ;
DEBAN, L ;
TORREMOCHA, I .
ANALYST, 1986, 111 (06) :631-634
[2]   DETERMINATION OF NITRITE ION IN UNUSED CUTTING FLUIDS AND CUTTING OILS USING A GAS-SENSING ELECTRODE METHOD [J].
CLARK, FRS ;
MACPHERSON, HB .
ANALYST, 1979, 104 (1237) :358-366
[3]   EFFECT OF ANIONIC SURFACTANTS ON CALCIUM ION-SELECTIVE ELECTRODES [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR ;
BIRCH, BJ .
ANALYST, 1980, 105 (1250) :426-431
[4]   USE OF DISPOSABLE CLEANUP COLUMNS FOR SELECTIVE REMOVAL OF HUMIC SUBSTANCES PRIOR TO MEASUREMENTS WITH A NITRATE ION-SELECTIVE ELECTRODE [J].
CSIKY, I ;
MARKOVARGA, G ;
JONSSON, JA .
ANALYTICA CHIMICA ACTA, 1985, 178 (02) :307-312
[5]   STUDIES OF CALCIUM ION-SELECTIVE ELECTRODES IN THE PRESENCE OF ANIONIC SURFACTANTS [J].
FREND, AJ ;
MOODY, GJ ;
THOMAS, JDR ;
BIRCH, BJ .
ANALYST, 1983, 108 (1290) :1072-1081
[6]   ALTERNATE WASHING METHOD FOR FLOW-THROUGH DETERMINATION OF AMMONIUM ION USING AN AMMONIA GAS ELECTRODE [J].
HARA, H ;
MOTOIKE, A ;
OKAZAKI, S .
ANALYTICAL CHEMISTRY, 1987, 59 (15) :1995-1999
[7]   VERSATILE MANIFOLD FOR THE SIMULTANEOUS DETERMINATION OF IONS IN FLOW-INJECTION ANALYSIS [J].
HAUSER, PC ;
TAN, SS ;
CARDWELL, TJ ;
CATTRALL, RW ;
HAMILTON, IC .
ANALYST, 1988, 113 (10) :1551-1555
[8]   EFFECT OF SURFACTANTS ON THE RESPONSE OF ION-SELECTIVE ELECTRODES WITH POLYVINYL-CHLORIDE) MEMBRANES [J].
HULANICKI, A ;
TROJANOWICZ, M ;
POBOZY, E .
ANALYST, 1982, 107 (1280) :1356-1362
[9]  
HULANICKI A, 1981, ION SELECTIVE ELECTR, V3, P103
[10]  
MIDGLEY D, 1991, POTENTIOMETRIC WATER, P374