Clinical usefulness of cystatin C for the estimation of glomerular filtration rate in type 1 diabetes - Reproducibility and accuracy compared with standard measures and iohexol clearance

被引:117
作者
Tan, GD
Lewis, AV
James, TJ
Altmann, P
Taylor, RP
Levy, JC [1 ]
机构
[1] Radcliffe Infirm, Oxford Ctr Diabet Endocrinol & Metab, Oxford OX2 6HE, England
[2] Oxford Radcliffe Hosp, Dept Clin Biochem, Oxford, England
[3] Oxford Radcliffe Hosp, Oxford Kidney Unit, Oxford, England
关键词
D O I
10.2337/diacare.25.11.2004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - Assessment and follow-up of early renal dysfunction is important in diabetic nephropathy. Plasma creatinine is insensitive for a glomerular filtration rate (GFR) >50 ml/min and creatinine clearance is unwieldy and subject to collection inaccuracies. We aimed to assess the reproducibility, reliability, and accuracy of plasma cystatin C as a measure of GFR ranging from normal to moderate impairment due to type 1 diabetes in the presence of a normal plasma creatinine concentration. RESEARCH. DESIGN AND METHODS - A sensitive immunoturbidimetric cystatin C assay was examined in 29 subjects with type 1 diabetes and 11 nondiabetic subjects. Duplicate measurements of the following were collected from each subject, 2 weeks apart: cystatin C, enzymatic plasma creatinine, 24-h creatinine clearance, GFR estimated from plasma creatinine by the Cockcroft-Gault equation, and iohexol clearance as a gold standard. RESULTS - Iohexol clearance ranged from 35 to 132 ml.min(-1).1.73 m(-2). Plasma cystatin C compared well with the other clinically used tests. The reliability of cystatin C, as assessed by the discriminant ratio, was superior to creatinine clearance (3.4 vs. 1.5, P G 0.001) and the correlation of cystatin C with iohexol clearance (Rs -0.80) was similar to that of creatinine clearance (Rs -0.74) and superior to that of plasma creatinine and the Cockcroft-Gault estimate (Rs -0.54 and 0.66, respectively). Duplicate estimations were used to provide an unbiased equation to convert plasma cystatin C to GFR. CONCLUSIONS - Based on this study, cystatin C is a more reliable measure of GFR than creatinine clearance, is more highly correlated with iohexol clearance than plasma creatinine, and is worthy of further investigation as a clinical measure of GFR in type 1 diabetes.
引用
收藏
页码:2004 / 2009
页数:6
相关论文
共 32 条
[1]   STRUCTURE AND EXPRESSION OF THE HUMAN CYSTATIN-C GENE [J].
ABRAHAMSON, M ;
OLAFSSON, I ;
PALSDOTTIR, A ;
ULVSBACK, M ;
LUNDWALL, A ;
JENSSON, O ;
GRUBB, A .
BIOCHEMICAL JOURNAL, 1990, 268 (02) :287-294
[2]  
ALLISON DB, 1993, NUTRITION, V9, P559
[3]  
ALTMAN DG, 1991, PRACTICAL STAT MED R, P293
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
BRENNER BM, 1981, ACTA ENDOCRINOL-COP, V97, P7
[6]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[7]   Twenty-four hour variations of cystatin C and total cysteine proteinase inhibitory activity in sera from healthy subjects [J].
Cimerman, N ;
Brguljan, PM ;
Krasovec, M ;
Suskovic, S ;
Kos, J .
CLINICA CHIMICA ACTA, 2000, 291 (01) :89-95
[8]   PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE [J].
COCKCROFT, DW ;
GAULT, MH .
NEPHRON, 1976, 16 (01) :31-41
[9]   Adult reference ranges for serum cystatin C, creatinine and predicted creatinine clearance [J].
Finney, H ;
Newman, DJ ;
Price, CP .
ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 :49-59
[10]  
FOSSATI P, 1994, CLIN CHEM, V40, P130