Deviations from the diffusion tensor model as revealed by contour plot visualization using high angular resolution diffusion-weighted imaging (HARDI)

被引:17
作者
Hirsch, JG
Schwenk, SM
Rossmanith, C
Hennerici, MG
Gass, A
机构
[1] Heidelberg Univ, Neurol Klin, D-68167 Mannheim, Germany
[2] Heidelberg Univ, Hosp Mannheim, Dept Neurol, D-6900 Heidelberg, Germany
关键词
diffusion; tensor; angular resolution; white matter; fiber structure;
D O I
10.1007/s10334-003-0011-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The standard diffusion tensor model is limited in its ability to provide detailed information about multidirectional fiber architecture in human white matter. Additional directional acquisition of diffusivity properties with high angular resolution diffusion-weighted imaging (HARDI) acquisition schemes may deliver more information on areas with fiber crossings than standard DTI. However, representation of the additional information and the rating and visualization of fiber complexity is challenging. We used projection 2D-plots in combination with a HARDI acquisition scheme of 129 diffusion directions and compared the spherical diffusion variance index (SDI) with the relative anisotropy index (RAI). In normal controls, white matter areas with unidirectional fiber arrangement and areas with more complex fiber composition were identified with this approach. HARDI confirms and can visualize deviations from the tensor-like representation, thereby providing information on fiber structure complexity, which may be of considerable interest for clinical studies.
引用
收藏
页码:93 / 102
页数:10
相关论文
共 56 条
[1]   Abnormal brain white matter in schizophrenia: a diffusion tensor imaging study [J].
Agartz, I ;
Andersson, JLR ;
Skare, S .
NEUROREPORT, 2001, 12 (10) :2251-2254
[2]  
Alexander AL, 2000, MAGNET RESON MED, V44, P283, DOI 10.1002/1522-2594(200008)44:2<283::AID-MRM16>3.0.CO
[3]  
2-V
[4]  
ALEXANDER DC, 2002, 10 P INT SOC MAGN RE, P1158
[5]  
Anderson A., 2002, 10 P INT SOC MAGN RE, P440
[6]  
Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
[7]  
2-O
[8]   A simplified method to measure the diffusion tensor from seven MR images [J].
Basser, PJ ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :928-934
[9]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[10]  
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]