Hepatic vein transit time of an ultrasound contrast agent: simplified procedure using pulse inversion imaging

被引:41
作者
Bang, N
Nielsen, MB
Rasmussen, AN
Osterhammel, PA
Pedersen, JF
机构
[1] Univ Copenhagen, Rigshosp, Dept Radiol, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Rigshosp, Dept Otorhinolaryngol Head & Neck Surg, DK-2100 Copenhagen, Denmark
[3] Univ Copenhagen, Glostrup Hosp, Dept Radiol, DK-2100 Copenhagen, Denmark
关键词
D O I
10.1259/bjr.74.884.740752
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to ascertain whether a new ultrasound technique, namely pulse inversion imaging, could assess the arrival of a contrast agent in the hepatic veins, and to describe possible advantages of this procedure in determining transit time over a previously described method based upon spectral Doppler quantification. 15 subjects were scanned using pulse inversion imaging. A bolus injection of 2.5 g Levovist (Schering AG, Berlin, Germany) 300 mg ml(-1) was given into an antecubital vein. Median transit times of 16 s (range 14-20 s) were found in patients with liver cirrhosis (n=4), 22 s (range 16-27 s) in patients with focal liver lesions (n=8) and 31 s (range 30 32 s) in control subjects (n=3). The maximum interobserver variation was 2 s and the maximum intraobserver variation was 3 s (n=10). Transit time was assessed by both pulse inversion imaging and spectral Doppler quantification in six patients. Comparison of the two methods showed transit times within 2 s apart in five patients and within 5 s apart in one patient. In conclusion, it is possible to assess transit time using pulse inversion imaging. This method is simpler than a previously described method requiring computer analysis. Moreover, several liver veins can be assessed simultaneously. Different transit times were observed in different liver veins in two patients with liver tumours. A short transit time (< 27 s) appears to be found only in patients with liver disease. After transit time assessment, it is possible to use the injected contrast agent for late phase imaging of the liver parenchyma.
引用
收藏
页码:752 / 755
页数:4
相关论文
共 4 条
[1]   Non-invasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent [J].
Albrecht, T ;
Blomley, MJK ;
Cosgrove, DO ;
Taylor-Robinson, SD ;
Jayaram, V ;
Eckersley, R ;
Urbank, A ;
Butler-Barnes, J ;
Patel, N .
LANCET, 1999, 353 (9164) :1579-1583
[2]   Liver vascular transit time analyzed with dynamic hepatic venography with bolus injections of an US contrast agent: Early experience in seven patients with metastases [J].
Blomley, MJK ;
Albrecht, H ;
Cosgrove, PO ;
Jayaram, V ;
Eckersley, RJ ;
Patel, N ;
Taylor-Robinson, T ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1998, 209 (03) :862-866
[3]   Pulse inversion imaging of liver blood flow - Improved method for characterizing focal masses with microbubble contrast [J].
Burns, PN ;
Wilson, SR ;
Simpson, DH .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :58-71
[4]   Pulse-inversion mode imaging of liver specific microbubbles: improved detection of subcentimetre metastases [J].
Harvey, CJ ;
Blomley, MJK ;
Eckersley, RJ ;
Heckemann, RA ;
Butler-Barnes, J ;
Cosgrove, DO .
LANCET, 2000, 355 (9206) :807-808