Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis

被引:667
作者
Smith, D
Spanel, P
机构
[1] Univ Keele, Sch Med, Inst Sci & Technol Med, Stoke On Trent ST4 7QB, Staffs, England
[2] Acad Sci Czech Republ, J Heyrovsky Inst Phys Chem, V Cermak Lab, CR-18223 Prague, Czech Republic
关键词
selected ion flow tube; SIFT-MS; chemical ionization; trace gas analysis; breath analysis; urine headspace analysis;
D O I
10.1002/mas.20033
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Selected ion flow tube mass spectrometry (SIFT-MS) is a new analytical technique for the real-time quantification of several trace gases simultaneously in air and breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas using H3O+, NO+, and O-2(+center dot) precursor ions. Reactions between the precursor ions and trace gas molecules proceed for an accurately defined time, the precursor and product ions being detected and counted by a downstream mass spectrometer, thus effecting quantification. Absolute concentrations of trace gases in single breath exhalation can be determined by SIFT-MS down to ppb levels, obviating sample collection and calibration. Illustrative examples of SIFT MS studies include (i) analysis of gases from combustion engines, animals and their waste, and food; (ii) breath and urinary headspace studies of metabolites, ethanol metabolism, elevated acetone during ovulation, and exogenous compounds; and (iii) urinary infection and the presence of tumors, the influence of dialysis on breath ammonia, acetone, and isoprene, and acetaldehyde released by cancer cells in vitro. Flowing afterglow mass spectrometry (FA-MS) is briefly described, which allows on-line quantification of deuterium in breath water vapor. (c) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:661 / 700
页数:40
相关论文
共 133 条
[1]   Quantification of acetonitrile in exhaled breath and urinary headspace using selected ion flow tube mass spectrometry [J].
Abbott, SM ;
Elder, JB ;
Spanel, P ;
Smith, D .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 228 (2-3) :655-665
[2]   SELECTED ION FLOW TUBE (SIFT) - TECHNIQUE FOR STUDYING ION-NEUTRAL REACTIONS [J].
ADAMS, NG ;
SMITH, D .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1976, 21 (3-4) :349-359
[3]  
ANICICH VG, 2003, JPL PUBLICATION, V319
[4]  
BALDWIN MA, 1999, ENCY SPECTROSCOPY SP
[5]   Ion mobility spectrometry - Principle and applications [J].
Baumbach, JI .
NACHRICHTEN AUS DER CHEMIE, 2001, 49 (01) :37-39
[6]  
BOHME DK, 1975, INTERACTIONS BETWEEN
[7]   A relationship between the kinetics and thermochemistry of proton transfer reactions in the gas phase [J].
Bouchoux, G ;
Salpin, JY ;
Leblanc, D .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1996, 153 (01) :37-48
[8]   EVALUATION OF OCCUPATIONAL EXPOSURE TO CARBON-DISULFIDE BY BLOOD, EXHALED AIR, AND URINE ANALYSIS [J].
CAMPBELL, L ;
JONES, AH ;
WILSON, HK .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1985, 8 (02) :143-153
[9]   CONTINUOUS-FLOW FAST-ATOM-BOMBARDMENT - RECENT ADVANCES AND APPLICATIONS [J].
CAPRIOLI, RM ;
SUTER, MJF .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1992, 118 :449-476
[10]   Emission of nitrogen oxides and ammonia from varying rates of applied synthetic urine and correlations with soil chemistry [J].
Clough, TJ ;
Sherlock, RR ;
Mautner, MN ;
Milligan, DB ;
Wilson, PF ;
Freeman, CG ;
McEwan, MJ .
AUSTRALIAN JOURNAL OF SOIL RESEARCH, 2003, 41 (03) :421-438