Ultra-high-Q microcavity operation in H2O and D2O -: art. no. 151118

被引:84
作者
Armani, AM
Armani, DK
Min, B
Vahala, KJ [1 ]
Spillane, SM
机构
[1] CALTECH, Dept Appl Phys, Pasadena, CA 91125 USA
[2] Hewlett Packard Labs, Quantum Sci Res, Palo Alto, CA 94304 USA
关键词
D O I
10.1063/1.2099529
中图分类号
O59 [应用物理学];
学科分类号
摘要
Optical microcavities provide a possible method for boosting the detection sensitivity of biomolecules. Silica-based microcavities are important because they are readily functionalized, which enables unlabeled detection. While silica resonators have been characterized in air, nearly all molecular detections are performed in solution. Therefore, it is important to determine their performance limits in an aqueous environment. In this letter, planar microtoroid resonators are used to measure the relationship between quality factor and toroid diameter at wavelengths ranging from visible to near-IR in both H2O and D2O, and results are then compared to predictions of a numerical model. Quality factors (Q) in excess of 10(8), a factor of 100 higher than previous measurements in an aqueous environment, are observed in both H2O and D2O. (C) 2005 American Institute of Physics.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 16 条
[1]   Ultra-high-Q toroid microcavity on a chip [J].
Armani, DK ;
Kippenberg, TJ ;
Spillane, SM ;
Vahala, KJ .
NATURE, 2003, 421 (6926) :925-928
[2]   Shift of whispering-gallery modes in microspheres by protein adsorption [J].
Arnold, S ;
Khoshsima, M ;
Teraoka, I ;
Holler, S ;
Vollmer, F .
OPTICS LETTERS, 2003, 28 (04) :272-274
[3]   Resonant-enhanced evanescent-wave fluorescence biosensing with cylindrical optical cavities [J].
Blair, S ;
Chen, Y .
APPLIED OPTICS, 2001, 40 (04) :570-582
[4]   Sensitive disk resonator photonic biosensor [J].
Boyd, RW ;
Heebner, JE .
APPLIED OPTICS, 2001, 40 (31) :5742-5747
[5]   Observation of critical coupling in a fiber taper to a silica-microsphere whispering-gallery mode system [J].
Cai, M ;
Painter, O ;
Vahala, KJ .
PHYSICAL REVIEW LETTERS, 2000, 85 (01) :74-77
[6]   Ultimate Q of optical microsphere resonators [J].
Gorodetsky, ML ;
Savchenkov, AA ;
Ilchenko, VS .
OPTICS LETTERS, 1996, 21 (07) :453-455
[7]   OPTICAL-CONSTANTS OF WATER IN 200-NM TO 200-MUM WAVELENGTH REGION [J].
HALE, GM ;
QUERRY, MR .
APPLIED OPTICS, 1973, 12 (03) :555-563
[8]   Optical waveguide sensor for on-line monitoring of bacteria [J].
Horváth, R ;
Pedersen, HC ;
Skivesen, N ;
Selmeczi, D ;
Larsen, NB .
OPTICS LETTERS, 2003, 28 (14) :1233-1235
[9]   Demonstration of ultra-high-Q small mode volume toroid microcavities on a chip [J].
Kippenberg, TJ ;
Spillane, SM ;
Vahala, KJ .
APPLIED PHYSICS LETTERS, 2004, 85 (25) :6113-6115
[10]   3-AMINOPROPYLTRIETHOXYSILANE (APES) - A NEW ADVANCE IN SECTION ADHESION [J].
MADDOX, PH ;
JENKINS, D .
JOURNAL OF CLINICAL PATHOLOGY, 1987, 40 (10) :1256-1257