Vascular complications of the intraaortic balloon pump in patients undergoing open heart operations: 15-year experience

被引:65
作者
Arafa, OE [1 ]
Pedersen, TH [1 ]
Svennevig, JL [1 ]
Fosse, E [1 ]
Geiran, OR [1 ]
机构
[1] Univ Oslo, Rikshosp, Dept Surg, N-0027 Oslo, Norway
关键词
D O I
10.1016/S0003-4975(98)01272-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The beneficial effects of the intraaortic balloon pump (IABP) in providing circulatory support must be weighed against its complications, particularly its vascular trauma. Methods. Five hundred nine patients who underwent open heart operations at our institution and who were treated with the IABP from January 1980 through December 1994 were studied retrospectively to assess IABP-related vascular complications and their independent preoperative predictors and the implications of IABP-related vascular complications on the patients' mortality, morbidity (clinical sepsis and organ failure), and longterm survival. Results. Early vascular complications occurred in 56 patients (11%) and major complications occurred in 41 patients (8%). The latter consisted of aortic perforation in 1 patient, aortoiliac dissection in 2 patients, and limb ischemia in 38 patients. Logistic regression analysis identified concomitant peripheral vascular disease (p < 0.001), elevated preoperative end-diastolic pressure, small body surface area, and large catheter size (p < 0.05) as independent risk factors for IABP-related major vascular complications in patients who survived the day of operation. Late IABP-related sequelae occurred in 10 patients, 9 of whom had had early vascular complications. The presence of vascular complications per se was not a significant independent factor among other risk factors for mortality, morbidity, or long-term survival. Conclusions. Careful clinical assessment of the aortofemoral vascular tree is a cornerstone of early diagnosis and early intervention and usually prevents limb loss. The significant decrease in major vascular complications that has occurred over the last 5 years can be explained by the increased use of catheters with smaller diameters. The timing of IABP insertion in relation to operation and the duration of IABP use were the only device-related risk factors identified for morbidity and survival. (Ann Thorac Surg 1999;67:645-51) (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:645 / 651
页数:7
相关论文
共 17 条
[1]   VASCULAR COMPLICATIONS FROM INTRAAORTIC BALLOONS - RISK ANALYSIS [J].
BARNETT, MG ;
SWARTZ, MT ;
PETERSON, GJ ;
NAUNHEIM, KS ;
PENNINGTON, DG ;
VACA, KJ ;
FIORE, AC ;
MCBRIDE, LR ;
PEIGH, P ;
WILLMAN, VL ;
KAISER, GC .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (01) :81-89
[2]   Vascular complications related to intraaortic balloon counterpulsation: An analysis of ten years experience [J].
Busch, T ;
Sirbu, H ;
Zenker, D ;
Dalichau, H .
THORACIC AND CARDIOVASCULAR SURGEON, 1997, 45 (02) :55-59
[3]  
*CDCP, 1994, EP INF VERS 6 WORD P
[4]   RESULTS OF INTRAAORTIC BALLOON PUMPING AFTER CARDIAC-SURGERY - EXPERIENCE WITH THE PERCOR BALLOON CATHETER [J].
DILELLO, F ;
MULLEN, DC ;
FLEMMA, RJ ;
ANDERSON, AJ ;
KLEINMAN, LH ;
WERNER, PH .
ANNALS OF THORACIC SURGERY, 1988, 46 (04) :442-446
[5]  
Dixon W. J., 1983, BMDP statistical software
[6]   COMPLICATIONS ASSOCIATED WITH PERCUTANEOUS PLACEMENT AND USE OF INTRAAORTIC BALLOON COUNTERPULSATION [J].
ELTCHANINOFF, H ;
DIMAS, AP ;
WHITLOW, PL .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) :328-332
[7]  
FUNK M, 1989, HEART LUNG, V18, P542
[8]   COMPLICATIONS OF THE INTRA-AORTIC BALLOON COUNTERPULSATION DEVICE - CLINICAL AND MORPHOLOGIC OBSERVATIONS IN 45 NECROPSY PATIENTS [J].
ISNER, JM ;
COHEN, SR ;
VIRMANI, R ;
LAWRINSON, W ;
ROBERTS, WC .
AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02) :260-268
[9]  
IVERSON LIG, 1987, AM J SURG, V154, P99
[10]   INTRAAORTIC BALLOON PUMPING 1967 THROUGH 1982 - ANALYSIS OF COMPLICATIONS IN 733 PATIENTS [J].
KANTROWITZ, A ;
WASFIE, T ;
FREED, PS ;
RUBENFIRE, M ;
WAJSZCZUK, W ;
SCHORK, MA .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (11) :976-983