Study and application of hole structures as gas gain devices for two dimensional high rate X-ray detectors

被引:35
作者
Sarvestani, A
Besch, HJ
Junk, M
Meissner, W
Sauer, N
Stiehler, R
Walenta, AH
Menk, RH
机构
[1] Univ Gesamthsch Siegen, Fachbereich Phys, D-57068 Siegen, Germany
[2] Sincrotrone Trieste, ELETTRA, I-34012 Trieste, Italy
关键词
hole counter; gas detector; high pressure; high rates; pixel detector; position interpolation;
D O I
10.1016/S0168-9002(98)00223-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent developments in hole structures seem to be a promising enrichment for gas-filled photon counters. Up to now. only few investigations of the performance and limitations of these structures have been carried out. In this work a micro-hole structure is presented together with investigations focused on applications with position sensitive pressurized X-ray detectors for synchrotron radiation. In particular, position resolution, gas gain, rate capability, drift field influence and pressure behavior have been studied. In addition. first two dimensional X-ray images have been measured using a gas amplifying micro-hole structure in combination with a resistive position encoding structure. Since different types of hole structures were tested, predictions of structure geometries adapted for specific applications were carried out. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:238 / 258
页数:21
相关论文
共 12 条
[1]  
[Anonymous], LBL3013
[2]   An interpolating 2D pixel readout structure for synchrotron X-ray diffraction in protein crystallography [J].
Besch, HJ ;
Junk, M ;
Meissner, W ;
Sarvestani, A ;
Stiehler, R ;
Walenta, AH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :244-248
[3]   MICROMEGAS: A high-granularity position-sensitive gaseous detector for high particle-flux environments [J].
Giomataris, Y ;
Rebourgeard, P ;
Robert, JP ;
Charpak, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 376 (01) :29-35
[4]  
HIMESH, STORK GRAPHICS
[5]  
LEHNERT H, 1993, THESIS U SIEGEN
[7]  
PIUZ F, 1982, 8211 CERN EF
[8]   A new type of proportional counter using a capillary plate [J].
Sakurai, H ;
Tamura, T ;
Gunji, S ;
Noma, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (03) :341-344
[9]  
SARVESTANI A, UNPUB SIMULATION MEA