Evaluation of wrought Zn-Al alloys (1, 3, and 5 wt % Al) through mechanical and in vivo testing for stent applications

被引:125
作者
Bowen, Patrick K. [1 ]
Seitz, Jan-Marten [1 ]
Guillory, Roger J., II [2 ]
Braykovich, Jacob P. [1 ]
Zhao, Shan [1 ]
Goldman, Jeremy [2 ]
Drelich, Jaroslaw W. [1 ]
机构
[1] Michigan Technol Univ, Dept Mat Sci & Engn, Houghton, MI 49931 USA
[2] Michigan Technol Univ, Dept Biomed Engn, Houghton, MI 49931 USA
关键词
zinc; alloys; bioabsorbable stent; histology; mechanical testing; corrosion; BIODEGRADABLE METALS; MAGNESIUM; ZINC; CORROSION; BEHAVIOR; RESTENOSIS; DESIGN;
D O I
10.1002/jbm.b.33850
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Special high grade zinc and wrought zinc-aluminum (Zn-Al) alloys containing up to 5.5 wt % Al were processed, characterized, and implanted in rats in search of a new family of alloys with possible applications as bioabsorbable endovascular stents. These materials retained roll-induced texture with an anisotropic distribution of the second-phase Al precipitates following hot-rolling, and changes in lattice parameters were observed with respect to Al content. Mechanical properties for the alloys fell roughly in line with strength (190-240 MPa yield strength; 220-300 MPa ultimate tensile strength) and elongation (15-30%) benchmarks, and favorable elastic ranges (0.19-0.27%) were observed. Intergranular corrosion was observed during residence of Zn-Al alloys in the murine aorta, suggesting a different corrosion mechanism than that of pure zinc. This mode of failure needs to be avoided for stent applications because the intergranular corrosion caused cracking and fragmentation of the implants, although the composition of corrosion products was roughly identical between non- and Al-containing materials. In spite of differences in corrosion mechanisms, the cross-sectional reduction of metals in murine aorta was nearly identical at 30-40% and 40-50% after 4.5 and 6 months, respectively, for pure Zn and Zn-Al alloys. Histopathological analysis and evaluation of arterial tissue compatibility around Zn-Al alloys failed to identify areas of necrosis, though both chronic and acute inflammatory indications were present. (c) 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 245-258, 2018.
引用
收藏
页码:245 / 258
页数:14
相关论文
共 51 条
[1]
[Anonymous], 1984, METALLOGRAPHY PRINCI
[2]
ASTM International, 2013, B613 ASTM INT
[3]
ASTM International, 1994, B557M94 ASTM INT
[4]
Corrosion mechanism applicable to biodegradable magnesium implants [J].
Atrens, Andrej ;
Liu, Ming ;
Abidin, Nor Ishida Zainal .
MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2011, 176 (20) :1609-1636
[5]
Ball A., 1969, J MET SCI, V3, P1, DOI [10.1179/msc.1969.3.1.1, DOI 10.1179/MSC.1969.3.1.1]
[6]
Barnhurst RJ., 1990, ZINC AND ZINC ALLOYS
[7]
Bolz A, 2001, US Patent, Patent No. [6287332 B1, 6287332]
[8]
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys [J].
Bowen, Patrick K. ;
Shearier, Emily R. ;
Zhao, Shan ;
Guillory, Roger J., II ;
Zhao, Feng ;
Goldman, Jeremy ;
Drelich, Jaroslaw W. .
ADVANCED HEALTHCARE MATERIALS, 2016, 5 (10) :1121-1140
[9]
Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents [J].
Bowen, Patrick K. ;
Guillory, Roger J., II ;
Shearier, Emily R. ;
Seitz, Jan-Marten ;
Drelich, Jaroslaw ;
Bocks, Martin ;
Zhao, Feng ;
Goldman, Jeremy .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 56 :467-472
[10]
Rates of in vivo (arterial) and in vitro biocorrosion for pure magnesium [J].
Bowen, Patrick K. ;
Drelich, Adam ;
Drelich, Jaroslaw ;
Goldman, Jeremy .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2015, 103 (01) :341-349